Static Ports Heater
| 30-31-03 | Static Ports Heater |
|---|
Applicable to: -
30-31-03-A One STBY static port heater inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 5 | No |
One STBY static ports heater
may be inoperative.
30-31-03-B Both STBY static port heater inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 4 | No |
(m)
1)
2)
Both STBY static ports heaters
may be inoperative provided that:
1)
The ADRs, heaters and failure
alerts associated with the CAPT and the F/O probes
(pitot, static, AOA, TAT) are checked operative
every day, and
2)
The OAT at the departure airport
is above 5 °C when the runway is contaminated
with water or slush.
30-31-03-C One or both F/O static port heater inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 4 | No |
(o)(m)
One or both F/O static ports
heaters may be inoperative provided that the ADRs, heaters
and failure alerts associated with the CAPT and the STBY probes (pitot, static, AOA, TAT)
are checked operative every day.
30-31-03-D One or both CAPT static port heater inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 4 | No |
(o)(m)
1)
2)
One or both CAPT static ports
heaters may be inoperative provided that:
1)
The ADRs, heaters and failure
alerts associated with the F/O and the STBY probes
(pitot, static, AOA, TAT) are checked operative
every day, and
2)
The OAT at the departure airport
is above 5 °C when the runway is contaminated
with water or slush.