Static Ports Heater


30-31-03Static Ports Heater
Applicable to: -
30-31-03-A One STBY static port heater inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
65No
One STBY static ports heater may be inoperative.

30-31-03-B Both STBY static port heater inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
64No
(m)
Both STBY static ports heaters may be inoperative provided that:

1)
The ADRs, heaters and failure alerts associated with the CAPT and the F/O probes (pitot, static, AOA, TAT) are checked operative every day, and

2)
The OAT at the departure airport is above 5 °C when the runway is contaminated with water or slush.

30-31-03-C One or both F/O static port heater inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
64No
(o)(m)
One or both F/O static ports heaters may be inoperative provided that the ADRs, heaters and failure alerts associated with the CAPT and the STBY probes (pitot, static, AOA, TAT) are checked operative every day.

30-31-03-D One or both CAPT static port heater inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
64No
(o)(m)
One or both CAPT static ports heaters may be inoperative provided that:

1)
The ADRs, heaters and failure alerts associated with the F/O and the STBY probes (pitot, static, AOA, TAT) are checked operative every day, and

2)
The OAT at the departure airport is above 5 °C when the runway is contaminated with water or slush.