W DOC AIRBUS | MMEL ITEMS A320F

LGCIU 2 Nose L/G Doors Open Proximity Detector


32-32-13LGCIU 2 Nose L/G Doors Open Proximity Detector
Applicable to: -
32-32-13-A Other proximity detectors operative
Repair intervalNbr installedNbr requiredPlacard
A 20No
(o)(m)
One or both may be inoperative for 7 flights provided that:

1)
The other proximity detectors are operative, and

2)
The origin of the failure is checked to be electrical.

32-32-13-B LGCIU 2 considered inoperative
Repair intervalNbr installedNbr requiredPlacard
A 20No
One or both may be inoperative for 7 flights provided that the LGCIU 2 is considered inoperative.