W DOC AIRBUS | MMEL ITEMS A320F

LGCIU 2 LH L/G Doors Open Proximity Detector


32-32-12LGCIU 2 LH L/G Doors Open Proximity Detector
Applicable to: -
32-32-12-A Other proximity detectors operative
Repair intervalNbr installedNbr requiredPlacard
A 10No
(o)(m)
May be inoperative for 7 flights provided that:

1)
The other proximity detectors are operative, and

2)
The origin of the failure is checked to be electrical.

32-32-12-B LGCIU 2 considered inoperative
Repair intervalNbr installedNbr requiredPlacard
A 10No
May be inoperative for 7 flights provided that the LGCIU 2 is considered inoperative.