Exit Marking Sign
| 33-51-01 | Exit Marking Sign |
|---|
Applicable to: -
33-51-01-A A maximum of three non-adjacent bulbs inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 6 | No |
A maximum of three non-adjacent
bulbs may be inoperative in one or more signs.
33-51-01-C Associated exit considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 6 | - | No |
One or more may be inoperative provided
that the associated exit is considered inoperative.
| 33-51-01 | Exit Marking Sign |
|---|
Applicable to: -
33-51-01-B A maximum of three non-adjacent LEDs inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 6 | 6 | No |
A maximum of three non-adjacent LEDs may be inoperative in one or more signs.
33-51-01-C Associated exit considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 6 | - | No |
One or more may be inoperative provided
that the associated exit is considered inoperative.
| 33-51-01 | Exit Marking Sign |
|---|
Applicable to: -
33-51-01-B A maximum of three non-adjacent LEDs inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 8 | 8 | No |
A maximum of three non-adjacent LEDs may be inoperative in one or more signs.
33-51-01-C Associated exit considered inoperative
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| - | 8 | - | No |
One or more may be inoperative provided
that the associated exit is considered inoperative.