Cabin DEU B
| 23-73-03-01 | Cabin DEU B |
|---|
Applicable to: -
23-73-03-01-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(o)
1)
2)
One or
more may be inoperative provided that :
1)
One DEU B and the associated
handset are operative at each pair of floor level exit doors, and
2)
The slide bottle pressure and door bottle
pressure associated with each affected DEU B are checked
on the associated direct reading pressure gauge before the first flight
of each day.
| 23-73-03-01 | Cabin DEU B |
|---|
Applicable to: -
23-73-03-01-B
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | - | - | No |
(o)
1)
2)
3)
4)
One or
more may be inoperative provided that:
1)
One DEU B and the associated
handset are operative at each pair of floor level exit doors, and
2)
The slide bottle pressure and door bottle
pressure associated with each affected DEU B are checked
on the associated direct reading pressure gauge before the first flight
of each day, and
3)
The associated lavatory fire extinguisher
system is checked operative, and
4)
The absence of smoke in the affected
lavatory is periodically checked.