Hot Air Pressure Regulating Valve
| 21-63-03 | Hot Air Pressure Regulating Valve |
|---|
Applicable to: -
NOTE:
- Unequal passengers distribution may cause high temperature in the rear cabin when the hot air pressure regulating valve is closed.
- The temperature in the cockpit may be low when the hot air pressure regulating valve is closed combined with single pack operation.
21-63-03-A Valve checked closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)
1)
2)
May be
inoperative provided that:
1)
The HOT AIR pb-sw is set to
OFF, and
2)
The hot air pressure regulating valve
is checked closed on the COND SD Page.
21-63-03-C Hot air pressure valve secured closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)(m)
May be inoperative provided that the hot air pressure regulating
valve is secured in the closed position.
| 21-63-03 | Hot Air Pressure Regulating Valve |
|---|
Applicable to: -
NOTE:
- Unequal passengers distribution may cause high temperature in the rear cabin when more than one trim air valves are inoperative or when the hot air pressure regulating valve is closed.
- The temperature in the cockpit may be low when the hot air pressure regulating valve is closed combined with single pack operation.
21-63-03-A Hot air pressure valve checked closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)
1)
2)
May be
inoperative in the closed position provided that:
1)
HOT AIR pb-sw is set to OFF,
and
2)
Hot Air Pressure Regulating Valve is
checked closed on the COND SD Page.
21-63-03-B All trim valve checked closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)
1)
2)
May be
inoperative in the open position provided that:
1)
HOT AIR pb-sw is set to OFF,
and
2)
All Trim Air Valves are checked closed
on the COND SD Page.
21-63-03-C Hot air pressure valve secured closed
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
(o)(m)
May be inoperative provided that the hot air pressure regulating
valve is secured in the closed position.