Zone Controller Channel


21-63-01Zone Controller Channel
Applicable to: -
21-63-01-A Primary channel inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
(o)
Primary channel may be inoperative provided that the hot air pressure regulating valve is checked closed on the COND SD Page.

NOTE:
  1. Unequal passengers distribution may cause high temperature in the rear cabin when the hot air pressure regulating valve is closed.
  2. The temperature in the cockpit may be low when the hot air pressure regulating valve is closed combined with single pack operation.
21-63-01-B Secondary channel inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
21No
Secondary channel may be inoperative provided that the minimum idle on ground is considered inoperative.

21-63-01-C Both channels inoperative
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
20No
(o)(m)
Primary and secondary channel may be inoperative provided that:

1)
The hot air pressure regulating valve is secured in the closed position, and

2)
The minimum idle on ground is considered inoperative.

NOTE:
  1. Unequal passengers distribution may cause high temperature in the rear cabin when the hot air pressure regulating valve is closed.
  2. The temperature in the cockpit may be low when the hot air pressure regulating valve is closed combined with single pack operation.