W DOC AIRBUS | MMEL ITEMS A320F

Avionics Extract Fan


21-26-02Avionics Extract Fan
Applicable to: -
NOTE:
During ground operation, correct avionics ventilation should be provided.
21-26-02-A VENT AVNCS SYS FAULT not displayed
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
10Yes
(o)
May be inoperative provided that:

1)
The blower fan is operative, and

2)
The EXTRACT pb-sw is set to OVRD, and

3)
Both air conditioning packs are operative, and

4)
The VENT AVNCS SYS FAULT alert is not displayed.

21-26-02-B Air conditioning inlet valve checked open
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
10Yes
(o)(m)
May be inoperative provided that:

1)
The blower fan is operative, and

2)
The EXTRACT pb-sw is set to OVRD, and

3)
Both air conditioning packs are operative, and

4)
The air conditioning inlet valve is checked open before each flight.

21-26-02-C Avionics ventilation system checked
Repair intervalNbr installedNbr requiredPlacard
C
13.04.2026
10Yes
(o)(m)
May be inoperative provided that:

1)
The blower fan is operative, and

2)
The EXTRACT pb-sw is set to OVRD, and

3)
Both air conditioning packs are operative, and

4)
The air conditioning inlet valve is secured in the open position, and

5)
The avionics ventilation system is checked before each flight.