HOT AIR FAULT
| 21-01-01-03 | HOT AIR pb-sw FAULT light |
|---|
Applicable to: -
21-01-01-03-A
| Repair interval | Nbr installed | Nbr required | Placard |
|---|---|---|---|
| C 13.04.2026 | 1 | 0 | Yes |
May be inoperative provided that all
zone duct temperature indications are operative on the COND SD Page.