Reactivation of Starter Valve Manual Control [IAE]
TASK 80-11-00-440-043-A
Reactivation of Starter Valve Manual Control
1. Reason for the Job
MMEL 80-11-01A
START VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 80-11-00-941-056-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-810-055-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-869-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:44:43 UTC
Reactivation of Starter Valve Manual Control
1. Reason for the Job
MMEL 80-11-01A
START VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TSM 80-00-00-810-801 | Failure of the Pneumatic Starter Valve on Engine 1 |
| TSM 80-00-00-810-802 | Failure of the Pneumatic Starter Valve on Engine 2 |
Subtask 80-11-00-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 80-11-00-810-055-A ** ON A/C NOT FOR ALL
A. Do the trouble shooting of the pneumatic starter valve system TSM 80-00-00-810-801 or TSM 80-00-00-810-802.
5. Close-upSubtask 80-11-00-869-054-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
Subtask 80-11-00-942-055-A ** ON A/C NOT FOR ALL B. Remove the WARNING NOTICE(S).