W DOC AIRBUS | AMM A320F

Reactivation of Starter Valve Manual Control [IAE]


TASK 80-11-00-440-043-A
Reactivation of Starter Valve Manual Control


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
MMEL 80-11-01A
START VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TSM 80-00-00-810-801
Failure of the Pneumatic Starter Valve on Engine 1
TSM 80-00-00-810-802
Failure of the Pneumatic Starter Valve on Engine 2
3. Job Set-up
Subtask 80-11-00-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure
Subtask 80-11-00-810-055-A ** ON A/C NOT FOR ALL
A. Do the trouble shooting of the pneumatic starter valve system TSM 80-00-00-810-801 or TSM 80-00-00-810-802.
5. Close-up
Subtask 80-11-00-869-054-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
Subtask 80-11-00-942-055-A ** ON A/C NOT FOR ALL
B. Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:44:43 UTC