W DOC AIRBUS | AMM A320F

Foreign Object Debris (FOD) Inspection of the Engine Starting System After Environmental Control System (ECS) Event [PW11]


TASK 80-11-00-210-803-A
Foreign Object Debris (FOD) Inspection of the Engine Starting System After Environmental Control System (ECS) Event


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the Job
This procedure gives the instructions to do a FOD check of the engine starting system in the event of a FOD event up-stream at the ECS.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
TASK 80-11-00-210-801-A
General Visual Inspection (GVI) of the Engine Starting System
TASK 80-11-01-000-801-A
Removal of the Starter
TASK 80-11-01-400-801-A
Installation of the Starter
TASK 80-11-03-000-801-A
Removal of the Starter Air Control Valve
TASK 80-11-03-400-801-A
Installation of the Starter Air Control Valve
TASK 80-11-49-000-802-A
Removal of the Lower Starter Air Duct
TASK 80-11-49-400-802-A
Installation of the Lower Starter Air Duct
3. Job Set-up
Subtask 80-11-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832).
4. Procedure
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 80-11-00-210-059-A ** ON A/C NOT FOR ALL
A. FOD Inspection of the Engine Starting System After ECS Event
   (1) Remove the starter air control valve (Ref. AMM TASK 80-11-03-000-801).
   (2) Remove the lower starter air duct (Ref. AMM TASK 80-11-49-000-802).
   (3) Inspect the starter air control valve, lower starter air duct and starter inlet:
     (a) If FOD or damage are present in the valve, duct or starter, replace the starter air valve (Ref. AMM TASK 80-11-03-000-801) and (Ref. AMM TASK 80-11-03-400-801).
     (b) If FOD or damage are present in the valve, duct or starter, replace the starter (Ref. AMM TASK 80-11-01-000-801) and (Ref. AMM TASK 80-11-01-400-801).
     (c) If FOD or damage are present in the duct, do a check of the duct (Ref. AMM TASK 80-11-00-210-801).
     (d) If there are no FOD or damage to the valve, duct or starter, go to the next step.
   (4) Install the lower starter air duct (Ref. AMM TASK 80-11-49-400-802).
   (5) Install the starter air control valve (Ref. AMM TASK 80-11-03-400-801).
5. Close-up
Subtask 80-11-00-410-067-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.