W DOC AIRBUS | AMM A320F

Check of the Starter Valve Manual Handle Position after Engine Start [CFML]


TASK 80-11-00-040-805-A
Check of the Starter Valve Manual Handle Position after Engine Start


1. Reason for the Job
MMEL 80-07-01A
START VALVE POSITION INDICATION ON THE ENGINE SD PAGE
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-803-A
Closing of the Fan Cowl Doors
3. Job Set-up
Subtask 80-11-00-010-066-A
A. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
4. Procedure
Subtask 80-11-00-210-058-A
A. After engine start cycle, check on starter valve that the manual handle is in closed position.
5. Close-up
Subtask 80-11-00-410-066-A
A. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 80-11-00-941-066-A
B. Safety Precautions
   (1) Tell the crew to make an entry in the log book.