Manually Operate the Starter Valve [CFMI]
TASK 80-11-00-040-041-A
Manually Operate the Starter Valve
1. Reason for the Job
MMEL 80-11-01A
START VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 80-11-00-010-053-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 80-11-00-869-052-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:44:00 UTC
Manually Operate the Starter Valve
1. Reason for the Job
MMEL 80-11-01A
START VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 438CR | |
| FOR [1000EM2] (ENGINE-2) | |
| 448CR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-710-003-A | Engine Automatic Start |
Subtask 80-11-00-010-053-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 80-11-00-869-052-A ** ON A/C NOT FOR ALL
A. Manual Control of the Starter Valve.
(2) After engine start cycle, check on starter valve that manual handle is in closed position. If not manually close the starter shutoff valve.
5. Close-upWARNING:
BE CAREFUL WHEN YOU OPERATE THE STARTER SHUTOFF VALVE WITH THE ENGINE RUNNING. OBEY THE SAFETY PRECAUTIONS.
CAUTION:
DO NOT OPERATE THE MANUAL HANDLE OF THE PNEUMATIC STARTER VALVE IF THE STARTER SYSTEM IS NOT PRESSURIZED. IF YOU DO, DAMAGE TO THE PNEUMATIC STARTER VALVE CAN OCCUR.
(1) Perform an engine start (Ref. AMM TASK 71-00-00-710-003) by operating the starter valve manually (Ref. FCOM 3-04-70 Pg8 Seq7 Rev30). (2) After engine start cycle, check on starter valve that manual handle is in closed position. If not manually close the starter shutoff valve.
Subtask 80-11-00-410-053-A ** ON A/C NOT FOR ALL
A. Close the access door on fan cowl :
(1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
Subtask 80-11-00-941-053-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
438CR
(2) FOR [1000EM2] (ENGINE-2)
448CR
B. Safety Precautions
(1) Install a WARNING NOTICE(S) in the cockpit to tell the persons that the pneumatic starter valve system is inoperative.
(2) Tell the crew to make an entry in the logbook.
(1) Install a WARNING NOTICE(S) in the cockpit to tell the persons that the pneumatic starter valve system is inoperative.
(2) Tell the crew to make an entry in the logbook.
Starter Valve