W DOC AIRBUS | AMM A320F

Installation of the Low Oil Pressure Switch [IAE]


TASK 79-34-15-400-010-A
Installation of the Low Oil Pressure Switch


WARNING: DO NOT LET ENGINE OIL STAY ON YOUR SKIN FOR A LONG TIME. FLUSH THE OIL FROM YOUR SKIN WITH WATER. THE OIL IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT LET ENGINE FUEL OR OIL FALL ON THE ENGINE. UNWANTED FUEL OR OIL MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FUEL OR OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 4000EN ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T
No specific
Torque wrench: range to between 105 and 95 lbf.in (1.19 and 1.07 m.daN ) T
No specific
Torque wrench: range to between 145 and 135 lbf.in (1.64 and 1.53 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.V01-002)
cleaning fluid
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
PACKING
AIPC 79-34-15-80-020
7
PACKING
AIPC 79-34-15-80-020
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 70-23-11-911-013-A
General Torque Tightening Techniques
TASK 70-23-13-911-010-A
Procedures for the Installation of Preformed Packings
TASK 70-23-15-912-010-A
Connection of Electrical Connectors
TASK 71-00-00-710-012-B
Test No.3 : Idle Leak Check
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
3. Job Set-up
Subtask 79-34-15-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 79-34-15-865-055-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
Subtask 79-34-15-865-056-A ** ON A/C NOT FOR ALL
WARNING: OPEN THE PROBE HEATER AND WINDOW HEATER CIRCUIT-BREAKERS BEFORE YOU OPEN THE PHC AND WHC CIRCUIT BREAKERS. IF YOU DO NOT OBEY THIS SEQUENCE:
  • THE PROBES WILL BECOME TOO HOT.
  • THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/PROBES/PHC/12DA1D03
122VUANTI ICE/WHC/25DG2W13
122VUANTI ICE/WHC/15DG1X13
122VUANTI ICE/PROBES/PHC/32DA3Y16
122VUANTI ICE/PROBES/PHC/22DA2Y12
Subtask 79-34-15-010-053-A ** ON A/C NOT FOR ALL
D. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-010)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 79-34-15-110-050-A ** ON A/C NOT FOR ALL
E. Clean these parts.
   (1) Clean these parts with a clean Textile-Lint free Cotton - (Material No.14SBA1) made moist with cleaning fluid (Material No.V01-002) .
     (a) The bolts (8).
     (b) The unions (2) and (6).
     (c) The mounting bracket.
     (d) The connections of the oil tubes (1) and (5).
4. Procedure
Subtask 79-34-15-210-050-A ** ON A/C NOT FOR ALL
A. Make sure that these parts are not damaged.
   (1) The bolts (8).
   (2) The unions (2) and (6).
   (3) The mounting bracket.
   (4) The electrical connector (4).
   (5) The oil tubes.
Subtask 79-34-15-410-051-A ** ON A/C NOT FOR ALL
B. Install the unions
   (1) Install new AIPC 79-34-15-80-020 PACKING (3) and AIPC 79-34-15-80-020 PACKING (7) (Ref. AMM TASK 70-23-13-911-010) to the unions (2) and (6).
   (2) Attach the unions to the switch (9).
   (3) TORQUE the unions to between 105 and 95 lbf.in (1.19 and 1.07 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
Subtask 79-34-15-420-051-A ** ON A/C NOT FOR ALL
C. Install the low oil pressure switch
   (1) Put the switch (9) on the bracket in the correct position for installation.
   (2) Attach the switch with the bolts (8).
   (3) TORQUE the bolts to between 44 and 36 lbf.in (0.50 and 0.41 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
   (4) Connect the oil tubes
     (a) Connect the oil tubes (1) and (5) to the switch (9).
     (b) TORQUE the oil tube nuts to between 145 and 135 lbf.in (1.64 and 1.53 m.daN ) T (Ref. AMM TASK 70-23-11-911-013).
     (c) Connect the electrical connector 4000EN-A (4) to the switch (9). (Ref. AMM TASK 70-23-15-912-010)
   (5) Remove the applicable covers/caps/plugs from the openings.
5. Close-up
Subtask 79-34-15-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 79-34-15-865-057-A ** ON A/C NOT FOR ALL
WARNING: OPEN THE PROBE HEATER AND WINDOW HEATER CIRCUIT-BREAKERS BEFORE YOU OPEN THE PHC AND WHC CIRCUIT BREAKERS. IF YOU DO NOT OBEY THIS SEQUENCE:
  • THE PROBES WILL BECOME TOO HOT.
  • THIS CAN CAUSE DAMAGE TO EQUIPMENT AND INJURY TO MAINTENANCE PERSONNEL.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/PROBES/PHC/12DA1D03
122VUANTI ICE/WHC/25DG2W13
122VUANTI ICE/WHC/15DG1X13
122VUANTI ICE/PROBES/PHC/32DA3Y16
122VUANTI ICE/PROBES/PHC/22DA2Y12
Subtask 79-34-15-865-058-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PITOT/13DA1D02
122VUANTI ICE/PROBES/2/TAT1DA2Y15
122VUANTI ICE/PROBES/2/PITOT3DA2Y14
122VUANTI ICE/PROBES/2/AOA4DA2Y13
122VUANTI ICE/PROBES/2/STATIC5DA2Y11
122VUANTI ICE/PROBES/3/PITOT3DA3Z16
122VUANTI ICE/PROBES/3/AOA4DA3Z15
122VUANTI ICE/PROBES/3/STATIC5DA3Z14
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
Subtask 79-34-15-710-051-B ** ON A/C NOT FOR ALL
D. Do an idle leak check (Ref. AMM TASK 71-00-00-710-012).
[Rev.10 from 2021] 2026.04.02 06:39:56 UTC