Installation of the Visual Indicator [CFMB]
TASK 79-21-30-400-001-A
Installation of the Visual Indicator
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 79-21-30-860-050-A ** ON A/C NOT FOR ALL
Subtask 79-21-30-420-050-A ** ON A/C NOT FOR ALL
Subtask 79-21-30-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:44:27 UTC
Installation of the Visual Indicator
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 110 and 95 lbf.in (1.24 and 1.07 m.daN ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP2101) | graphite grease |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
Subtask 79-21-30-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
Subtask 79-21-30-010-053-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
B. Make sure that the fan cowl doors are open: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 79-21-30-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Visual Indicator
PRE SB CFM 79-0014
END OF PRE SB CFM 79-0014
POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
Visual Indicator (POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036) ** ON A/C NOT FOR ALL
END OF POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
(1) Lubricate the threads of two bolts (40) with graphite grease (Material No.CP2101) .
(2) Attach the visual indicator (60) to the bracket (50) with two bolts (40) and two nuts (30).
(3) TORQUE the nuts (30) to between 110 and 95 lbf.in (1.24 and 1.07 m.daN )
.
(4) Remove the CAP - BLANKING and PLUG - BLANKING from the connectors and the receptacles.
(5) Connect the connectors (10) and (20) to the visual indicator (60).
5. Close-upPRE SB CFM 79-0014
END OF PRE SB CFM 79-0014
POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
Visual Indicator (POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036) ** ON A/C NOT FOR ALL END OF POST SB CFM 79-0014 or POST SB CFM 79-0023 or POST SB CFM 79-0036
(1) Lubricate the threads of two bolts (40) with graphite grease (Material No.CP2101) .
(2) Attach the visual indicator (60) to the bracket (50) with two bolts (40) and two nuts (30).
(3) TORQUE the nuts (30) to between 110 and 95 lbf.in (1.24 and 1.07 m.daN )
. (4) Remove the CAP - BLANKING and PLUG - BLANKING from the connectors and the receptacles.
(5) Connect the connectors (10) and (20) to the visual indicator (60).
Subtask 79-21-30-410-051-A ** ON A/C NOT FOR ALL