W DOC AIRBUS | AMM A320F

Detailed Visual Inspection of the Hydraulic Control Unit [CFMI]


TASK 78-31-51-210-040-A
Detailed Visual Inspection of the Hydraulic Control Unit


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-31-51-000-040-A
Removal of the Hydraulic Control Unit
TASK 78-31-51-400-040-A
Installation of the Hydraulic Control Unit
TASK 78-31-51-920-040-A
Replacement of the Hydraulic Control Unit Filter
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 78-31-51-941-059-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-51-010-066-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-51-040-061-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041)
Subtask 78-31-51-010-068-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 78-31-51-210-055-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the hydraulic Control Unit as follows :
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Inspect the hydraulic control unit for :


A.Damage
No damage permitted
If you find some damage, replace the hydraulic control unit (Ref. AMM TASK 78-31-51-000-040) and (Ref. AMM TASK 78-31-51-400-040)
B.Crack
No crack permitted
If there is crack, replace the hydraulic control unit (Ref. AMM TASK 78-31-51-000-040) and (Ref. AMM TASK 78-31-51-400-040)
C.Hydraulic leakage
No leakage permitted
If there is leakage, check connecting nuts and nipples for correct torque (Ref. AMM TASK 78-31-51-400-040). If the leakage persists, replace the preformed packing (Ref. AMM TASK 78-31-51-000-040) and (Ref. AMM TASK 78-31-51-400-040). If the leakage persists, replace the nipples (Ref. AMM TASK 78-31-51-000-040) and (Ref. AMM TASK 78-31-51-400-040)
2.Inspect the related hardware of the HCU for :


A.Damage
No damage permitted
If you find some damage, replace the defective part (Ref. AMM TASK 78-31-51-000-040) and (Ref. AMM TASK 78-31-51-400-040)
3.Inspect the clogging indicator for :


A.Indication
The indicator must not be extended
If the indicator is extended, replace the hydraulic filter and set clogging indicator operational (Ref. AMM TASK 78-31-51-920-040)
4.Inspect the electrical connector for :


A.Tightness
The blue marks of the HCU electrical connector must be covered by the pylon electrical harness connectors
If the blue marks of the HCU electrical connector are visible, tighten the pylon electrical harness connectors
5. Close-up
Subtask 78-31-51-410-063-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-51-440-059-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041)
Subtask 78-31-51-410-065-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.02 06:38:07 UTC