Detailed Visual Inspection of the Hydraulic Pipes [CFMI]
TASK 78-31-49-210-001-A
Detailed Visual Inspection of the Hydraulic Pipes
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-49-941-062-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-210-050-A ** ON A/C NOT FOR ALL
Subtask 78-31-49-410-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:38:05 UTC
Detailed Visual Inspection of the Hydraulic Pipes
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-49-000-001-A | Removal of the Return Pipe of the Left Latch |
| TASK 78-31-49-000-002-A | Removal of the Upper Supply Pipe of the Left Latch |
| TASK 78-31-49-000-003-A | Removal of the Lower Supply Pipe of the Left Latch |
| TASK 78-31-49-000-004-A | Removal of the Lower Supply Pipe of the Right Latch |
| TASK 78-31-49-000-005-A | Removal of the Upper Supply Pipe of the Right Latch |
| TASK 78-31-49-000-006-A | Removal of the Return Pipe of the Right Latch |
| TASK 78-31-49-000-007-A | Removal of the Upper Rod Supply Hose |
| TASK 78-31-49-000-008-A | Removal of the Rod Supply Pipe of the Left Actuator |
| TASK 78-31-49-000-009-A | Removal of the Head Supply Pipe of the Left Actuator |
| TASK 78-31-49-000-011-A | Removal of the Head Supply Pipe of the Right Actuator |
| TASK 78-31-49-000-012-A | Removal of the Upper Head Supply Hose |
| TASK 78-31-49-000-013-A | Removal of the Head Supply Junction Pipe |
| TASK 78-31-49-000-014-A | Removal of the Left or Right Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-000-015-A | Removal of the Left or Right Inner Supply Pipe of the Door-opening Actuator |
| TASK 78-31-49-000-017-A | Removal of the Upper Swivel Joints |
| TASK 78-31-49-000-018-A | Removal of the Hydraulic Line Upper, Double and Lower Brackets |
| TASK 78-31-49-000-020-A | Removal of the Lower Swivel Joints |
| TASK 78-31-49-000-021-A | Removal of the Interface Bracket, HCU Bracket and Hydraulic Line Middle Bracket |
| TASK 78-31-49-000-022-A | Removal of the Lower Head Supply Hose |
| TASK 78-31-49-000-023-A | Removal of the Lower Rod Supply Hose |
| TASK 78-31-49-000-024-A | Removal of the Rod Supply Junction Pipe |
| TASK 78-31-49-000-040-A | Removal of the Rod Supply Pipe of the Right Actuator |
| TASK 78-31-49-400-001-A | Installation of the Return Pipe of the Left Latch |
| TASK 78-31-49-400-002-A | Installation of the Upper Supply Pipe of the Left Latch |
| TASK 78-31-49-400-003-A | Installation of the Lower Supply Pipe of the Left Latch |
| TASK 78-31-49-400-004-A | Installation of the Lower Supply Pipe of the Right Latch |
| TASK 78-31-49-400-005-A | Installation of the Upper Supply Pipe of the Right Latch |
| TASK 78-31-49-400-006-A | Installation of the Return Pipe of the Right Latch |
| TASK 78-31-49-400-007-A | Installation of the Upper Rod Supply Hose |
| TASK 78-31-49-400-008-A | Installation of the Rod Supply Pipe of the Left Actuator |
| TASK 78-31-49-400-009-A | Installation of the Head Supply Pipe of the Left Actuator |
| TASK 78-31-49-400-011-A | Installation of the Head Supply Pipe of the Right Actuator |
| TASK 78-31-49-400-012-A | Installation of the Upper Head Supply Hose |
| TASK 78-31-49-400-013-A | Installation of the Head Supply Junction Pipe |
| TASK 78-31-49-400-014-A | Installation of the Left or Right Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-400-015-A | Installation of the Left or Right Inner Supply Pipe of the Door-Opening Actuator |
| TASK 78-31-49-400-017-A | Installation of the Upper Swivel Joints |
| TASK 78-31-49-400-018-A | Installation of the Hydraulic Line Upper, Double and Lower Brackets |
| TASK 78-31-49-400-020-A | Installation of the Lower Swivel Joints |
| TASK 78-31-49-400-021-A | Installation of the Interface Bracket, HCU Bracket and Hydraulic Line Middle Bracket |
| TASK 78-31-49-400-022-A | Installation of the Lower Head Supply Hose |
| TASK 78-31-49-400-023-A | Installation of the Lower Rod Supply Hose |
| TASK 78-31-49-400-024-A | Installation of the Rod Supply Junction Pipe |
| TASK 78-31-49-400-040-A | Installation of the Rod Supply Pipe of the Right Actuator |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
Subtask 78-31-49-941-062-A ** ON A/C NOT FOR ALL
A. On the panel 115VU:
Subtask 78-31-49-010-063-A ** ON A/C NOT FOR ALL - Put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 78-31-49-040-050-A ** ON A/C NOT FOR ALL Subtask 78-31-49-010-064-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-49-210-050-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of hydraulic pipes as follows:
5. Close-upSubtask 78-31-49-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-49-440-050-A ** ON A/C NOT FOR ALL Subtask 78-31-49-410-061-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Forward Frame of Half Door