W DOC AIRBUS | AMM A320F

Removal of the Left Electrical Harness [CFMI]


TASK 78-31-42-000-040-A
Removal of the Left Electrical Harness


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
PLIERS - NOSE, SOFT, LONG
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
3. Job Set-up
Subtask 78-31-42-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-42-010-061-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-42-040-057-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 78-31-42-010-064-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 78-31-42-020-054-A ** ON A/C NOT FOR ALL
A. Loosen the coupling nuts of the electrical connectors with PLIERS - NOSE, SOFT, LONG from the following components :
   (1) The stow switches of the upper and lower blocker doors (1).
   (2) The beam electrical harness (2).
   (3) Disconnect the electrical connectors.
   (4) Remove nuts, washers, bolts, clamps and two half clamps with attach the electrical harness on pipes.
   (5) Remove bolts, nuts and clamps which attach the electrical harness on supports.
   (6) Remove the electrical harness.
   (7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.02 07:41:55 UTC