Operational Check of Actuator Secondary Lock Mechanism [CFMI]
TASK 78-31-41-720-040-A
Operational Check of Actuator Secondary Lock Mechanism
1. Reason for the Job
Refer to the MPD TASK: 783100-C6
OPERATIONAL CHECK OF ACTUATOR SECONDARY LOCK MECHANISM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-41-941-059-A ** ON A/C NOT FOR ALL
Subtask 78-31-41-869-057-B ** ON A/C NOT FOR ALL
Subtask 78-31-41-440-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:20:56 UTC
Operational Check of Actuator Secondary Lock Mechanism
1. Reason for the Job
Refer to the MPD TASK: 783100-C6
OPERATIONAL CHECK OF ACTUATOR SECONDARY LOCK MECHANISM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-00-710-040-A | Operational Test of the Thrust Reverser System |
| TASK 78-31-00-710-040-A-01 | Operational Test of the Thrust Reverser without CFDS - Engine not Running |
| TASK 78-31-00-710-040-A-02 | Operational Test of the Thrust Reverser without CFDS - Engine Running |
| TASK 78-31-41-000-040-A | Removal of the Blocker Door Hydraulic Actuators |
| TASK 78-31-41-400-040-A | Installation of the Blocker Door Hydraulic Actuators |
Subtask 78-31-41-941-059-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-41-010-063-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-41-040-059-A ** ON A/C NOT FOR ALL 4. Procedure(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-41-869-057-B ** ON A/C NOT FOR ALL
A. Operational Test of the Secondary Lock.
(2) Turn the manual unlock shaft on the blocker door latch to the unlock position with a 5/16 in. (7.9 mm) wrench.
(4) Push in on the blocker door until the latch engages to close the blocker door.
(5) Put the thermal blanket (40) on the blocker door latch (15). Turn the Dzus fastener on the blanket (40) 1/4 turn to lock it.
5. Close-upNOTE: The procedure is the same for each actuator.
(1) Turn the Dzus fastener on the thermal blanket (40) to loosen it and remove the blanket from the blocker door latch (15). (2) Turn the manual unlock shaft on the blocker door latch to the unlock position with a 5/16 in. (7.9 mm) wrench.
NOTE: The manual unlock shaft can be accessed through a slot on the right or left side of the blocker door latch.
(3) Pull the blocker door by hands to make sure that the door cannot open. If the door opens, replace the actuator (Ref. AMM TASK 78-31-41-000-040) or (Ref. AMM TASK 78-31-41-400-040). (4) Push in on the blocker door until the latch engages to close the blocker door.
(5) Put the thermal blanket (40) on the blocker door latch (15). Turn the Dzus fastener on the blanket (40) 1/4 turn to lock it.
Subtask 78-31-41-440-057-A ** ON A/C NOT FOR ALL
A. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
(1) Remove the lock-out pin from the operating control lever on the HCU.
Subtask 78-31-41-869-060-A ** ON A/C NOT FOR ALL Subtask 78-31-41-410-061-A ** ON A/C NOT FOR ALL (1) Remove the lock-out pin from the operating control lever on the HCU.
Hydraulic Actuator and Latch