W DOC AIRBUS | AMM A320F

General Visual Inspection of Actuator Rod End Attachments (Blocker Doors Deployed) [CFMI]


TASK 78-31-41-210-803-A
General Visual Inspection of Actuator Rod End Attachments (Blocker Doors Deployed)


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Refer to the MPD TASK: 783100-C8
GENERAL VISUAL INSPECTION OF ACTUATOR ROD END ATTACHMENTS (BLOCKER DOORS DEPLOYED)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 78-31-41-000-040-A
Removal of the Blocker Door Hydraulic Actuators
TASK 78-31-41-000-802-A
Removal of the Blocker Door Hydraulic Actuator Clevis
TASK 78-31-41-400-040-A
Installation of the Blocker Door Hydraulic Actuators
TASK 78-31-41-400-802-A
Installation of the Blocker Door Hydraulic Actuator Clevis
3. Procedure
Subtask 78-31-41-210-064-A ** ON A/C NOT FOR ALL
A. Do an inspection of the clevis and the related hardware as follows:
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Do the inspection of the clevis and the related hardware for:


A.Damage
No damage permitted
If you find damage, replace the defective part (Ref. AMM TASK 78-31-41-000-802) and (Ref. AMM TASK 78-31-41-400-802).
B.Missing
None permitted
If you find a part missing, replace the defective part (Ref. AMM TASK 78-31-41-000-802) and (Ref. AMM TASK 78-31-41-400-802).
2.Examine the blocker door actuator for:


A.Scratch
No scratch permitted
If there is a scratch, replace the actuator (Ref. AMM TASK 78-31-41-000-040) and (Ref. AMM TASK 78-31-41-400-040).
[Rev.10 from 2021] 2026.04.02 06:38:00 UTC