Check Secondary Lock Mechanism Indicator Position of Pivoting Door Actuators (Lock) [CFMB]
TASK 78-31-41-210-041-B
Check Secondary Lock Mechanism Indicator Position of Pivoting Door Actuators (Lock)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-41-941-053-A ** ON A/C NOT FOR ALL
Subtask 78-31-41-210-050-A ** ON A/C NOT FOR ALL
Subtask 78-31-41-440-052-A ** ON A/C NOT FOR ALL Subtask 78-31-41-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:24:25 UTC
Check Secondary Lock Mechanism Indicator Position of Pivoting Door Actuators (Lock)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-41-000-001-A | Removal of the Blocker Door Hydraulic Actuator |
| TASK 78-31-41-400-001-A | Installation of the Blocker Door Hydraulic Actuator |
Subtask 78-31-41-941-053-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-41-010-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position .
Subtask 78-31-41-040-052-A ** ON A/C NOT FOR ALL 4. Procedure(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position .
Subtask 78-31-41-210-050-A ** ON A/C NOT FOR ALL
A. Replace the actuator
(1) With the blocker doors in closed position examine if the locking indicator of the actuator is in lock position. If the locking indicator is not in lock position, replace the actuator (Ref. AMM TASK 78-31-41-000-001) and (Ref. AMM TASK 78-31-41-400-001).
5. Close-up(1) With the blocker doors in closed position examine if the locking indicator of the actuator is in lock position. If the locking indicator is not in lock position, replace the actuator (Ref. AMM TASK 78-31-41-000-001) and (Ref. AMM TASK 78-31-41-400-001).
Subtask 78-31-41-440-052-A ** ON A/C NOT FOR ALL Subtask 78-31-41-410-053-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Blocker Door Actuator