General Visual Inspection of Blocker Door Latches, Hinges and Adjacent Structure (Blocker Doors Deployed) [CFMI]
TASK 78-31-19-210-041-A
General Visual Inspection of Blocker Door Latches, Hinges and Adjacent Structure (Blocker Doors Deployed)
1. Reason for the Job
Refer to the MPD TASK: 783000-C1
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-19-941-055-A ** ON A/C NOT FOR ALL
Subtask 78-31-19-210-053-A ** ON A/C NOT FOR ALL
Subtask 78-31-19-080-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:20:49 UTC
General Visual Inspection of Blocker Door Latches, Hinges and Adjacent Structure (Blocker Doors Deployed)
1. Reason for the Job
Refer to the MPD TASK: 783000-C1
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| HIX3005 | 1 | SAFETY SLEEVE - PIVOTING DOOR ACTUATOR |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-19-000-040-A | Removal of the Blocker Door Latches |
| TASK 78-31-19-400-040-A | Installation of the Blocker Door Latches |
| TASK 78-32-11-000-040-A | Removal of the Left or Right Half Door of Thrust Reverser |
| TASK 78-32-11-400-040-A | Installation of the Left or Right Half Door of Thrust Reverser |
| TASK 78-32-41-000-042-A | Removal of the Latch Fitting and Latch Back Plate |
| TASK 78-32-41-080-040-A | Removal of the Safety Sleeve from Blocker Door Actuator |
| TASK 78-32-41-400-042-A | Installation of the Latch Fitting and Latch Back Plate |
| TASK 78-32-41-480-040-A | Installation of the Safety Sleeve on Blocker Door Actuator |
| TASK 78-32-41-860-040-A | Manual Deployment of the Blocker Door |
| TASK 78-32-41-860-041-A | Manual Stowing of the Blocker Door |
Subtask 78-31-19-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-19-010-060-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-19-040-056-A ** ON A/C NOT FOR ALL Subtask 78-31-19-860-063-A ** ON A/C NOT FOR ALL Subtask 78-31-19-480-053-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
E. Install the HIX3005 SAFETY SLEEVE - PIVOTING DOOR ACTUATOR on blocker door actuator (Ref. AMM TASK 78-32-41-480-040).
4. ProcedureSubtask 78-31-19-210-053-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the pivoting door latch and the related hardware as follows :
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Do the inspection of the pivoting door latch for: | | |
| A.Damage | No damage permitted | If you find some damage, replace blocker door latch (Ref. AMM TASK 78-31-19-000-040) and (Ref. AMM TASK 78-31-19-400-040) |
| B.Hydraulic leakage | No hydraulic leakage permitted | If there is leakage, check nipples for correct torque (Ref. AMM TASK 78-31-19-400-040) |
| | | If the leakage persists, replace the preformed packing (Ref. AMM TASK 78-31-19-000-040) and (Ref. AMM TASK 78-31-19-400-040) |
| | | If the leakage persists, replace the blocker door latch (Ref. AMM TASK 78-31-19-000-040) and (Ref. AMM TASK 78-31-19-400-040) |
| 2.Do the inspection of the related hardware for: | | |
| A.Damage | No damage permitted | If you find some damage, replace the defective part (Ref. AMM TASK 78-31-19-000-040) and (Ref. AMM TASK 78-31-19-400-040) |
| 3.Do the inspection of the latch fitting (hinge) and the roller for: | | |
| A.Damage | No damage permitted | If you find some damage replace the latch fitting (Ref. AMM TASK 78-32-41-000-042) and (Ref. AMM TASK 78-32-41-400-042). |
| 4.Do the inspection of the forward frame around the latch for: | | |
| A.Damage | No damage permitted | If you find some damage replace the half door (Ref. AMM TASK 78-32-11-000-040) and (Ref. AMM TASK 78-32-11-400-040). |
Subtask 78-31-19-080-053-A ** ON A/C NOT FOR ALL
A. Remove the safety sleeve (HIX3005) from the blocker door actuator (Ref. AMM TASK 78-32-41-080-040).
Subtask 78-31-19-860-058-A ** ON A/C NOT FOR ALL B. Stowing of the blocker door:
Subtask 78-31-19-440-055-A ** ON A/C NOT FOR ALL Subtask 78-31-19-410-057-A ** ON A/C NOT FOR ALL CAUTION:
BLOCKER DOOR LATCH MUST BE OPENED WHEN YOU CLOSE THE BLOCKER DOOR OR DAMAGE CAN OCCUR.
(1) Bring blocker doors to stow position manually (Ref. AMM TASK 78-32-41-860-041). D. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Blocker Door Latches