W DOC AIRBUS | AMM A320F

Detailed Visual Inspection of the Blocker Door Latches, Hinges and Adjacent Structure [CFMB]


TASK 78-31-19-210-040-B
Detailed Visual Inspection of the Blocker Door Latches, Hinges and Adjacent Structure


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
HIX3005
1
SAFETY SLEEVE - PIVOTING DOOR ACTUATOR
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-31-19-000-001-A
Removal of the Blocker Door Latches
TASK 78-31-19-400-001-A
Installation of the Blocker Door Latches
TASK 78-32-11-000-002-A
Removal of the Left or Right Half Door of Thrust Reverser
TASK 78-32-11-400-002-A
Installation of the Left or Right Half Door of Thrust Reverser
TASK 78-32-41-000-003-A
Removal of the Latch Fitting and Latch Back Plate
TASK 78-32-41-080-001-A
Removal of the Safety Sleeve from Blocker Door Actuator
TASK 78-32-41-400-003-A
Installation of the Latch Fitting and Latch Back Plate
TASK 78-32-41-480-001-A
Installation of the Safety Sleeve on Blocker Door Actuator
TASK 78-32-41-860-001-A
Manual Deployment of the Blocker Door
TASK 78-32-41-860-002-A
Manual Stowing of the Blocker Door
3. Job Set-up
Subtask 78-31-19-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-19-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position in the right side of the engine.
Subtask 78-31-19-040-051-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 78-31-19-860-060-A ** ON A/C NOT FOR ALL
D. Deploy the blocker door manually (Ref. AMM TASK 78-32-41-860-001).
Subtask 78-31-19-480-054-A ** ON A/C NOT FOR ALL
E. Install the HIX3005 SAFETY SLEEVE - PIVOTING DOOR ACTUATOR on the blocker door actuator (Ref. AMM TASK 78-32-41-480-001) .
4. Procedure
Subtask 78-31-19-210-050-A ** ON A/C NOT FOR ALL
A. Do a Visual Inspection of the Blocker Door Latch and the Related Hardware
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Examine the blocker door latch for:


A.Damage
No damage permitted
If you find some damage, replace blocker door latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)
B.Crack
No crack permitted
If there is crack, replace the blocker door latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)
C.Missing of surface treatment
No missing permitted
If there is any missing of surface treatment, replace the blocker door latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)
D.Hydraulic leakage
No hydraulic leakage permitted
If there is leakage, check nipples for correct torque (Ref. AMM TASK 78-31-19-400-001)


If the leakage continues, replace the preformed packing (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)


If the leakage continues, replace the blocker door latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)
2.Examine the related hardware for:


A.Damage
No damage permitted
If you find some damage, replace the defective part (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001)
3.Examine the latch fitting (hinge) and the roller for:


A.Damage
No damage permitted
If there is damage replace the latch fitting (Ref. AMM TASK 78-32-41-000-003)and (Ref. AMM TASK 78-32-41-400-003).
B.Crack
No crack permitted
If there is crack replace the latch fitting (Ref. AMM TASK 78-32-41-000-003)and (Ref. AMM TASK 78-32-41-400-003).
C.Jamming
The roller must be free to turn.
If the roller is not free remove it (Ref. AMM TASK 78-32-41-000-003)and reinstall it (Ref. AMM TASK 78-32-41-400-003).
4.Examine the forward frame around the latch for:


A.Crack, damage
None permitted.
If you find some crack(s) or other damage replace the half door (Ref. AMM TASK 78-32-11-000-002)and (Ref. AMM TASK 78-32-11-400-002).
5. Close-up
Subtask 78-31-19-080-054-A ** ON A/C NOT FOR ALL
A. Remove the safety sleeve (HIX-3005) from the blocker door actuator (Ref. AMM TASK 78-32-41-080-001).
Subtask 78-31-19-860-052-A ** ON A/C NOT FOR ALL
B. Stowing of the blocker door:
CAUTION: BLOCKER DOOR LATCH MUST BE OPENED WHEN YOU CLOSE THE BLOCKER DOOR OR DAMAGE CAN OCCUR.
   (1) Move the blocker doors to the closed position manually (Ref. AMM TASK 78-32-41-860-002).
Subtask 78-31-19-440-051-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 78-31-19-410-052-A ** ON A/C NOT FOR ALL
D. Close Access
   (1) Make sure that the work area is clean and clear of tool(s) and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 03:24:19 UTC