Detailed Visual Inspection of the Stow-switches [CFMI]
TASK 78-31-18-210-040-A
Detailed Visual Inspection of the Stow-switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-18-941-052-A ** ON A/C NOT FOR ALL
Subtask 78-31-18-210-051-A ** ON A/C NOT FOR ALL
Subtask 78-31-18-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:37:59 UTC
Detailed Visual Inspection of the Stow-switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | PLIERS - NOSE, SOFT, LONG |
| No specific | AR | WARNING NOTICE(S) |
| HIX3005 | 1 | SAFETY SLEEVE - PIVOTING DOOR ACTUATOR |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-18-000-040-A | Removal Blocker Door Stow-switch |
| TASK 78-31-18-400-040-A | Installation Blocker Door Stow-switch |
| TASK 78-32-41-080-040-A | Removal of the Safety Sleeve from Blocker Door Actuator |
| TASK 78-32-41-480-040-A | Installation of the Safety Sleeve on Blocker Door Actuator |
| TASK 78-32-41-860-040-A | Manual Deployment of the Blocker Door |
| TASK 78-32-41-860-041-A | Manual Stowing of the Blocker Door |
Subtask 78-31-18-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-18-010-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-18-040-053-A ** ON A/C NOT FOR ALL Subtask 78-31-18-860-055-A ** ON A/C NOT FOR ALL Subtask 78-31-18-481-051-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
E. Install the HIX3005 SAFETY SLEEVE - PIVOTING DOOR ACTUATOR on blocker door actuator (Ref. AMM TASK 78-32-41-480-040).
4. ProcedureSubtask 78-31-18-210-051-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the stow switch and the related hardware, the lever of the stow switch and the electrical connector as follows :
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Do the inspection of the stow switch and the related hardware for: | | |
| A.Damage | No damage permitted | If you find some damage, replace the defective part (Ref. AMM TASK 78-31-18-000-040) and (Ref. AMM TASK 78-31-18-400-040) |
| 2.Do the inspection of the lever of stow switch for : | | |
| A.Crack | No crack allowed | If there is crack, replace the stow switch (Ref. AMM TASK 78-31-18-000-040) and (Ref. AMM TASK 78-31-18-400-040) |
| 3.Inspect the electrical connector for : | | |
| A.Tightness | The blue mark of the stow switch connector must be covered by the blue mark of the electrical harness | If the blue mark of the stow switch connector is visible, tighten the electrical harness connector with PLIERS - NOSE, SOFT, LONG |
Subtask 78-31-18-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
Subtask 78-31-18-081-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
B. Remove the safety sleeve (HIX-3005) from the blocker door actuator (Ref. AMM TASK 78-32-41-080-040).
Subtask 78-31-18-860-056-A ** ON A/C NOT FOR ALL C. Close the blocker door
Subtask 78-31-18-440-053-A ** ON A/C NOT FOR ALL Subtask 78-31-18-410-054-A ** ON A/C NOT FOR ALL CAUTION:
BLOCKER DOOR LATCH MUST BE OPENED WHEN YOU CLOSE THE BLOCKER DOOR OR DAMAGE CAN OCCUR.
(1) Manually bring blocker doors to stow position (Ref. AMM TASK 78-32-41-860-041).