W DOC AIRBUS | AMM A320F

Detailed Visual Inspection of the Stow-switches [CFMB]


TASK 78-31-18-210-001-A
Detailed Visual Inspection of the Stow-switches


FIN: 4104KS1 ** ON A/C NOT FOR ALL
FIN: 4104KS2 ** ON A/C NOT FOR ALL
FIN: 4104KS3 ** ON A/C NOT FOR ALL
FIN: 4104KS4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
PLIERS - NOSE, SOFT, LONG
No specific
AR
WARNING NOTICE(S)
HIX3005
1
SAFETY SLEEVE - PIVOTING DOOR ACTUATOR
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-31-18-000-001-A
Removal of the Blocker Door Stow-switch
TASK 78-31-18-400-001-A
Installation of the Blocker Door Stow-switch
TASK 78-32-41-080-001-A
Removal of the Safety Sleeve from Blocker Door Actuator
TASK 78-32-41-480-001-A
Installation of the Safety Sleeve on Blocker Door Actuator
TASK 78-32-41-860-001-A
Manual Deployment of the Blocker Door
TASK 78-32-41-860-002-A
Manual Stowing of the Blocker Door
3. Job Set-up
Subtask 78-31-18-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-18-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-18-040-051-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 78-31-18-860-052-A ** ON A/C NOT FOR ALL
D. Deploy the blocker door manually (Ref. AMM TASK 78-32-41-860-001).
Subtask 78-31-18-481-050-A ** ON A/C NOT FOR ALL
E. Install the HIX3005 SAFETY SLEEVE - PIVOTING DOOR ACTUATOR on blocker door actuator (Ref. AMM TASK 78-32-41-480-001).
4. Procedure
Subtask 78-31-18-210-050-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the stow switch and the related hardware, the lever of the stow switch and the electrical connector as follows :
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Examine the stow switch and the related hardware for:


A.Damage
No damage permitted
If you find some damage, replace the defective part (Ref. AMM TASK 78-31-18-000-001) and (Ref. AMM TASK 78-31-18-400-001)
2.Examine the lever of stow switch for :


A.Crack
No crack permitted
If there is crack, replace the stow switch (Ref. AMM TASK 78-31-18-000-001) and (Ref. AMM TASK 78-31-18-400-001)
3.Examine the electrical connector for :


A.Tightness
The blue mark of the stow switch connector must be covered by the blue mark of the electrical harness
If the blue mark of the stow switch connector can be seen, tighten the electrical harness connector with the PLIERS - NOSE, SOFT, LONG
5. Close-up
Subtask 78-31-18-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
Subtask 78-31-18-081-050-A ** ON A/C NOT FOR ALL
B. Remove the safety sleeve (HIX-3005) from the blocker door actuator (Ref. AMM TASK 78-32-41-080-001).
Subtask 78-31-18-860-053-A ** ON A/C NOT FOR ALL
C. Close bring blocker
CAUTION: BLOCKER DOOR LATCH MUST BE OPENED WHEN YOU CLOSE THE BLOCKER DOOR OR DAMAGE CAN OCCUR.
   (1) Manually move the blocker doors to closed position (Ref. AMM TASK 78-32-41-860-002).
Subtask 78-31-18-440-051-A ** ON A/C NOT FOR ALL
D. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 78-31-18-410-052-A ** ON A/C NOT FOR ALL
E. Close Access
   (1) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:24:16 UTC