Installation of the Beam Electrical Harness [CFMI]
TASK 78-31-17-400-041-A
Installation of the Beam Electrical Harness
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 78-31-17-860-051-A ** ON A/C NOT FOR ALL
Subtask 78-31-17-420-054-A ** ON A/C NOT FOR ALL
Subtask 78-31-17-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:37:58 UTC
Installation of the Beam Electrical Harness
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP2318) | blindexite RT 342-2 |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-00-710-040-A-01 | Operational Test of the Thrust Reverser without CFDS - Engine not Running |
| TASK 78-31-00-710-040-A-02 | Operational Test of the Thrust Reverser without CFDS - Engine Running |
| TASK 78-31-00-710-040-A | Operational Test of the Thrust Reverser System |
| TASK 78-31-00-710-040-A-01 | Operational Test of the Thrust Reverser without CFDS - Engine not Running |
| TASK 78-31-00-710-040-A-02 | Operational Test of the Thrust Reverser without CFDS - Engine Running |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
Subtask 78-31-17-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 78-31-17-010-071-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
B. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-17-040-062-A ** ON A/C NOT FOR ALL 4. Procedure(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-17-420-054-A ** ON A/C NOT FOR ALL
A. Installation of the Beam Electrical Harness
(2) Install the beam electrical harness.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL
(3) Connect the electrical harness to the blocker door deploy switch.
(4) Tighten the coupling nuts of the deploy switch connectors with PLIERS - NOSE, SOFT, LONG.
(5) Install the three bolts which attach the harness.
(6) TORQUE the bolts to between 80 and 70 lbf.in (0.90 and 0.79 m.daN )
.
(7) Connect the forward frame electrical harness on to the beam harness connector.
(8) Install the deploy switch access door.
(9) Install the three screws.
(10) TORQUE the screws to between 45 and 35 lbf.in (0.51 and 0.40 m.daN )
.
5. Close-upWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Apply a layer of blindexite RT 342-2 (Material No.CP2318) on the harness surface in contact with the forward frame. (2) Install the beam electrical harness.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL (4) Tighten the coupling nuts of the deploy switch connectors with PLIERS - NOSE, SOFT, LONG.
(5) Install the three bolts which attach the harness.
(6) TORQUE the bolts to between 80 and 70 lbf.in (0.90 and 0.79 m.daN )
. (7) Connect the forward frame electrical harness on to the beam harness connector.
(8) Install the deploy switch access door.
(9) Install the three screws.
(10) TORQUE the screws to between 45 and 35 lbf.in (0.51 and 0.40 m.daN )
. Subtask 78-31-17-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-17-440-055-A ** ON A/C NOT FOR ALL Subtask 78-31-17-410-060-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
Subtask 78-31-17-710-054-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
D. Do an operational test of the thrust reverser system from the CFDS (Ref. AMM TASK 78-31-00-710-040).
NOTE: As an alternative procedure, you can do this operational test without the CFDS:
- first method with engine stopped (Ref. AMM TASK 78-31-00-710-040).
- second method with engine in operation (Ref. AMM TASK 78-31-00-710-040).