Removal of the Blocker Doors Actuation Levers [CFMI]
TASK 78-31-17-000-042-A
Removal of the Blocker Doors Actuation Levers
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-17-941-062-A ** ON A/C NOT FOR ALL
Subtask 78-31-17-020-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:20:37 UTC
Removal of the Blocker Doors Actuation Levers
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-17-000-040-A | Removal of the Blocker Door Deploy Switch |
| TASK 78-32-41-000-040-A | Removal of the Lower Blocker Door |
| TASK 78-32-41-000-041-A | Removal of the Upper Blocker Door |
Subtask 78-31-17-941-062-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-17-010-065-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position on the right side of the engine.
Subtask 78-31-17-040-059-A ** ON A/C NOT FOR ALL Subtask 78-31-17-010-066-A ** ON A/C NOT FOR ALL 4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position on the right side of the engine.
Subtask 78-31-17-020-057-A ** ON A/C NOT FOR ALL
A. Removal of the Blocker Doors Actuation Levers
PRE SB RA32078-39
(1) Remove the bolts which attach the trigger.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL
POST SB RA32078-39
(2) Remove the screw and the nut which attach the trigger.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL
END OF SB RA32078-39
(3) Remove the trigger.
(4) Remove the lower or upper blocker door (Ref. AMM TASK 78-32-41-000-040) or (Ref. AMM TASK 78-32-41-000-041).
(5) Remove the bolt and the lock washer which attach the lever on the beam.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL
(6) Remove the inner and outer levers.
PRE SB RA32078-39
(1) Remove the bolts which attach the trigger.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL POST SB RA32078-39
(2) Remove the screw and the nut which attach the trigger.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL END OF SB RA32078-39
(3) Remove the trigger.
(4) Remove the lower or upper blocker door (Ref. AMM TASK 78-32-41-000-040) or (Ref. AMM TASK 78-32-41-000-041).
(5) Remove the bolt and the lock washer which attach the lever on the beam.
Blocker Door Switch, Actuation Levers and Beam Electrical Harness PRE SB RA32078-39 ** ON A/C NOT FOR ALL
Blocker Door Switch, Actuation Levers and Beam Electrical Harness POST SB RA32078-39 ** ON A/C NOT FOR ALL