Detailed Visual Inspection of the Hydraulic Contol Unit Pressure Switches [CFMB]
TASK 78-31-16-210-041-A
Detailed Visual Inspection of the Hydraulic Contol Unit Pressure Switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-16-941-051-A ** ON A/C NOT FOR ALL
Subtask 78-31-16-210-050-A ** ON A/C NOT FOR ALL
Subtask 78-31-16-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:24:03 UTC
Detailed Visual Inspection of the Hydraulic Contol Unit Pressure Switches
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-16-000-041-A | Removal of the Hydraulic Control Unit Pressure Switch |
| TASK 78-31-16-400-041-A | Installation of the Hydraulic Control Unit Pressure Switch |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 78-31-16-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-16-010-051-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-16-040-051-A ** ON A/C NOT FOR ALL Subtask 78-31-16-010-052-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
D. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-31-16-210-050-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the pressure switch, the related hardware and of the pylon electrical connector as follows:
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Inspect the pressure switch for: | | |
| A.Damage | No damage allowed | If you find some damage, replace the pressure switch. (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| B.Crack | No crack allowed | If there is crack, replace the pressure switch. (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| C.Hydraulic Leakage | No leakage allowed | If there is leakage examine the bolts for correct torque (Ref. AMM TASK 78-31-16-400-041) |
| | | If the leakage persists, replace the packing (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| | | If the leakage persists, replace the pressure switch (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| 2.Inspect the related hardware of the pressure switch for: | | |
| A.Damage | No damage allowed | If you find some damage, replace the defective part. (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| B.Missing | No missing hardware permitted | If you find some hardware missing, install replacement parts. (Ref. AMM TASK 78-31-16-000-041) and (Ref. AMM TASK 78-31-16-400-041). |
| 3.Inspect the pylon electrical connector for: | | |
| A.Tightness | The blue mark of the pressure switch must be covered by the blue mark of the pylon electrical connector. | If the blue mark of the pressure switch is visible, tighten the electrical connector with the softnose pliers. |
Subtask 78-31-16-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).
Subtask 78-31-16-440-051-A ** ON A/C NOT FOR ALL Subtask 78-31-16-410-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
(3) Remove the access platform(s).