W DOC AIRBUS | AMM A320F

Cancel Frequency Analysis [CFMB]


TASK 77-32-34-860-045-A
Cancel Frequency Analysis


FIN: 2EV ** ON A/C NOT FOR ALL
1. Reason for the Job
You can use this procedure when the Frequency Analysis is not necessary.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
3. Job Set-up
Subtask 77-32-34-861-068-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 77-32-34-865-077-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2/EVMU1EVR44
Subtask 77-32-34-869-096-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the MCDU 1(2), get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
   (2) Push the line key adjacent to the EVMU indication: the first EVMU page comes into view.
4. Procedure
Subtask 77-32-34-860-059-A ** ON A/C NOT FOR ALL
A. Cancel Frequency Analysis Demand
ACTION
RESULT
1.Push the NEXT PAGE mode key
The second EVMU page comes into view
2.Push the line key adjacent to the FREQUENCY ANALYSIS indication
The EVMU FREQUENCY ANALYSIS menu comes into view
3.Push the line key adjacent to the CANCEL LEFT (RIGHT) related to the engine for which you cancel the Frequency Analysis demand.
The information "wait for system response" comes into view and disappeared to show the EVMU FREQUENCY ANALYSIS menu
4.Push the line key adjacent to the LOAD LEFT (RIGHT) related to the engine for which you want to check the cancellation.
You can read REQUEST OFF FOR N1(N2)
5.On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.

5. Close-up
Subtask 77-32-34-862-068-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:37:44 UTC