Visual inspection of the ECU Air Cooling Tubes and Ducts [CFMI]
TASK 75-24-49-210-040-A
Visual inspection of the ECU Air Cooling Tubes and Ducts
1. Reason for the Job
To check if the ECU cooling tubes are worn or damaged and are attached correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-24-49-941-057-A ** ON A/C NOT FOR ALL
Subtask 75-24-49-210-055-B ** ON A/C NOT FOR ALL
Subtask 75-24-49-410-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:36:54 UTC
Visual inspection of the ECU Air Cooling Tubes and Ducts
1. Reason for the Job
To check if the ECU cooling tubes are worn or damaged and are attached correctly.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 75-24-49-941-057-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-24-49-010-063-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
4. Procedure(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
Subtask 75-24-49-210-055-B ** ON A/C NOT FOR ALL
A. Do a visual inspection of the flexible ECU cooling ducts which is connected to the ECU and the inlet cowl.
(1) If required, clean dirty parts with clean cloth.
(a) Check the flex duct for cracks and holes. No holes or cracks allowed. Replace defective parts.
(b) Check the duct clamps for corrosion, damage, loose or missing fasteners. Repair corrosion, replace damaged of missing fasteners.
5. Close-up(1) If required, clean dirty parts with clean cloth.
(a) Check the flex duct for cracks and holes. No holes or cracks allowed. Replace defective parts.
(b) Check the duct clamps for corrosion, damage, loose or missing fasteners. Repair corrosion, replace damaged of missing fasteners.
Subtask 75-24-49-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
ECU Air Cooling Tubes