W DOC AIRBUS | AMM A320F

Installation of the Active Clearance Control (ACC) Heat Shield Blankets [PW11]


TASK 75-24-41-400-802-A
Installation of the Active Clearance Control (ACC) Heat Shield Blankets


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AND THE ADJACENT COMPONENTS AFTER ENGINE SHUTDOWN. THE ENGINE, THE ENGINE OIL AND THE ADJACENT COMPONENTS CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
Torque wrench: range to between 17.0 and 15.0 lbf.in (0.19 and 0.17 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 78-36-00-410-802-A
Closing of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 75-24-41-941-058-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 75-24-41-010-060-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
   (2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
Subtask 75-24-41-040-055-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser System for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Make sure that you did the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 75-24-41-010-061-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Make sure that the right thrust-reverser cowl-door is open (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure
CAUTION: DO NOT LET THE THERMAL INSULATION BLANKETS BECOME WET. FLUIDS CAN GO INTO THE VENT HOLES OF THE BLANKETS AND MAKE THE INSULATION UNSATISFACTORY.
CAUTION: BE CAREFUL WHEN YOU MOVE THE THERMAL INSULATION BLANKETS. IF YOU DO NOT HOLD THE BLANKETS CORRECTLY, THEY CAN FOLD BECAUSE OF THEIR OWN WEIGHT. DO NOT STEP ON OR PUT OBJECTS ON THE BLANKETS. DO NOT PUT THE BLANKETS ON SURFACES THAT CAN CAUSE DAMAGE. HOLD THE BLANKETS ON THEIR THICKEST PARTS. IF YOU DO NOT OBEY THESE INSTRUCTIONS, DAMAGE TO THE BLANKETS CAN OCCUR.
Subtask 75-24-41-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the ACC Heat Shield Blankets
   (1) Put the upper ACC shield blanket (3) in position on the ACC duct.
   (2) Install the lower ACC shield blanket (2) on the upper ACC shield blanket (3) with the four retainers (1).
   (3) TORQUE the four retainers (1) to between 17.0 and 15.0 lbf.in (0.19 and 0.17 m.daN ) T.
5. Close-up
Subtask 75-24-41-410-050-A ** ON A/C NOT FOR ALL
Subtask 75-24-41-440-052-A ** ON A/C NOT FOR ALL
B. Do the reactivation of the thrust reverser system after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 75-24-41-410-051-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.02 06:37:17 UTC