W DOC AIRBUS | AMM A320F

Inspection/Check of the High Pressure Turbine Clearance Control Valve (HPTCC) [CFMI]


TASK 75-21-10-200-001-A
Inspection/Check of the High Pressure Turbine Clearance Control Valve (HPTCC)


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 70-51-00-230-001-A
Fluorescent-Penetrant Inspection-Portable Water-Washable
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 75-21-10-000-001-A
Removal of the High Pressure Turbine Active Clearance Control (HPTACC) Valve
TASK 75-21-10-400-001-A
Installation of the High Pressure Turbine Active Clearance Control (HPTACC) Valve
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 75-21-10-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-21-10-010-050-A ** ON A/C NOT FOR ALL
B. Open fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 75-21-10-040-050-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 75-21-10-010-052-A ** ON A/C NOT FOR ALL
D. Open thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 75-21-10-210-050-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the HPT active clearance control (HPTACC) valve as follows:
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Valve housing for :
  • Cracks
Not serviceable
Replace the valve (Ref. AMM TASK 75-21-10-000-001) and (Ref. AMM TASK 75-21-10-400-001)
  • Deformation
Not serviceable
Replace the valve (Ref. AMM TASK 75-21-10-000-001) and (Ref. AMM TASK 75-21-10-400-001)
  • Nicks or scratches
Any amount

2.Flanged joints for :


  • Loose bolts or nuts
Not serviceable
TORQUE the bolts (Ref. AMM TASK 75-21-10-400-001)
  • Cracks
Not serviceable
Replace the valve (Ref. AMM TASK 75-21-10-000-001) and (Ref. AMM TASK 75-21-10-400-001)
  • Deformed or bent
Not serviceable
Replace the valve (Ref. AMM TASK 75-21-10-000-001) and (Ref. AMM TASK 75-21-10-400-001)
Subtask 75-21-10-230-050-A ** ON A/C NOT FOR ALL
B. If a crack is suspected after visual inspection, do a fluorescent penetrant inspection to confirm existence of the crack (Ref. AMM TASK 70-51-00-230-001).
5. Close-up
Subtask 75-21-10-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 75-21-10-440-050-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041)
Subtask 75-21-10-410-053-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.02 06:36:53 UTC