Removal of the Fuel Filter Differential Pressure Switch [CFMI]
TASK 73-34-15-000-040-A
Removal of the Fuel Filter Differential Pressure Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-34-15-861-051-A ** ON A/C NOT FOR ALL Subtask 73-34-15-941-053-A ** ON A/C NOT FOR ALL
Subtask 73-34-15-020-052-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:35:43 UTC
Removal of the Fuel Filter Differential Pressure Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CONTAINER 5 L (1.32 USGAL) |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
Subtask 73-34-15-861-051-A ** ON A/C NOT FOR ALL Subtask 73-34-15-941-053-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(b) Make sure that the ENG/MASTER CONTROL SWITCH is in OFF position.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 73-34-15-865-060-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(b) Make sure that the ENG/MASTER CONTROL SWITCH is in OFF position.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 73-34-15-865-061-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG1 | 1QG | A08 |
| 121VU | FUEL/LP VALVE/MOT2/ENG1 | 3QG | M25 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG2 | 2QG | A09 |
| 121VU | FUEL/LP VALVE/MOT2/ENG2 | 4QG | M26 |
D. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 73-34-15-869-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | ENGINE/1/HP FUEL SOV | 1KC1 | A01 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | ENGINE/2/HP FUEL SOV | 1KC2 | A02 |
E. Do the EIS start procedure (upper and lower ECAM DU's only) (Ref. AMM TASK 31-60-00-860-001).
(1) Make sure that on the SD fuel page the LP valve is shown closed.
Subtask 73-34-15-010-053-A ** ON A/C NOT FOR ALL (1) Make sure that on the SD fuel page the LP valve is shown closed.
F. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 73-34-15-020-052-B ** ON A/C NOT FOR ALL
A. Removal of the Fuel Filter Differential Pressure Switch
(1) Disconnect the electrical connector 4000EL-A from the fuel-filter differential-pressure switch (20).
(2) Cut the lockwire and remove the thermal blanket (5) from the switch (20).
(3) Put a COVER - PROTECTION on the electrical connector.
(4) Put a CONTAINER 5 L (1.32 USGAL) below the switch (20). Disconnect the fuel tubes (35) and (40) from the switch and let the fuel drain.
(5) Remove the unions (30) and packings (25) from the switch (20). Discard the packings (25).
(6) Remove the bolts (10) and washers (15) from the switch (20). Remove the switch from the bracket.
(7) Put a COVER - PROTECTION on the unions, the switch and the fuel tubes
(1) Disconnect the electrical connector 4000EL-A from the fuel-filter differential-pressure switch (20).
(2) Cut the lockwire and remove the thermal blanket (5) from the switch (20).
(3) Put a COVER - PROTECTION on the electrical connector.
(4) Put a CONTAINER 5 L (1.32 USGAL) below the switch (20). Disconnect the fuel tubes (35) and (40) from the switch and let the fuel drain.
(5) Remove the unions (30) and packings (25) from the switch (20). Discard the packings (25).
(6) Remove the bolts (10) and washers (15) from the switch (20). Remove the switch from the bracket.
(7) Put a COVER - PROTECTION on the unions, the switch and the fuel tubes
Fuel Filter Differential Pressure Switch