Engine Interface Unit (EIU) DISCRETE OUTPUTS Simulation [PW11]


TASK 73-25-34-860-803-A
Engine Interface Unit (EIU) DISCRETE OUTPUTS Simulation


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 73-25-34-861-062-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 73-25-34-865-074-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
** ON A/C NOT FOR ALL
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
Subtask 73-25-34-860-087-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the left or right MCDU, get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
4. Procedure
Subtask 73-25-34-860-088-A ** ON A/C NOT FOR ALL
A. DISCRETE OUTPUTS P TYPE
ACTION
RESULT
1.Push the line key adjacent to the EIU1(EIU2) indication on the MCDU.
The EIU1(EIU2) menu comes into view.
2.Push the line key adjacent to the TESTS indication.
On the MENU page, the TEST menu comes into view.
3.Push the line key adjacent to the SPECIFIC DATA indication.
On the MENU page, the SPECIFIC DATA menu comes into view.
4.Push the line key adjacent to the DISCRETE OUTPUTS SIMUL indication.
The DISCRETE OUTPUTS SIMUL menu comes into view.
5.Push the line key adjacent to DISCRETE OUTPUTS P TYPE indication.
The DISCRETE OUTPUTS SIMUL (P TYPE: 28VDC/OPEN) menu comes into view.
On page 1:
  • APU BOOST CMD1
  • APU BOOST CMD2
  • OLP AND GND1
  • OLP AND GND2
    On page 2:
  • LIGHT FAULT ON.
NOTE: When the DSO type P commands an electrical 28 VDC, then the status displayed shall be 1.

When the DSO type P commands an electrical open circuit, then the status displayed shall be 0.

When the DSO type P is failed, then the status displayed shall be a dash (-).
6.On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.

7.Stop the MCDU.

Subtask 73-25-34-860-089-A ** ON A/C NOT FOR ALL
B. DISCRETE OUTPUTS N TYPE
ACTION
RESULT
1.Push the line key adjacent to the EIU1(EIU2) indication on the MCDU.
The EIU1(EIU2) menu comes into view.
2.Push the line key adjacent to the TESTS indication.
On the MENU page, the TEST menu comes into view.
3.Push the line key adjacent to the SPECIFIC DATA indication.
On the MENU page, the SPECIFIC DATA menu comes into view.
4.Push the line key adjacent to the DISCRETE OUTPUTS SIMUL indication.
The DISCRETE OUTPUTS SIMUL menu comes into view.
5.Push the line key adjacent to DISCRETE OUTPUTS N TYPE indication.
The DISCRETE OUTPUTS SIMUL (N TYPE: GND/OPEN) menu comes into view.
On page 1:
  • HPSOV CLOSED
  • N2 NOT BELOW IDLE
  • TLA IN T/O POS
  • PACK VLV CLOSURE
    On page 2:
  • NAI P/B FAULT
  • SLAT EXTEND INHIB.
NOTE: When the DSO type N commands an electrical ground circuit, then the status displayed shall be 1.

When the DSO type N commands an electrical open circuit, then the status displayed shall be 0.

When the DSO type N is failed, then the status displayed shall be a dash (-).
6.On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.

7.Stop the MCDU.

5. Close-up
Subtask 73-25-34-860-097-A ** ON A/C NOT FOR ALL
A. Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
Subtask 73-25-34-862-062-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).