1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
3. Job Set-up
Subtask 73-25-34-861-055-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 73-25-34-865-064-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/ENG2/FADEC B4KS2Q40
4. Procedure
Subtask 73-25-34-860-051-A ** ON A/C NOT FOR ALL
A. On the left or right MCDU get the SYSTEM REPORT/TEST page. (Ref. AMM TASK 31-32-00-860-012).
ACTION
RESULT
1.Push the line key adjacent to the EIU1 (EIU2) indication.
The EIU1 (EIU2) menu comes into view.
2.Push the line key adjacent to the DISCRETE OUTPUTS indication.
The DISCRETE OUTPUTS menu comes into view.
NOTE: The screen shows the actual output status at the time of the request. The output status are frozen after you enter this menu. You can only change the status if you push the key adjacent to the indication.
3.Push the line key adjacent to the indication of the data status you have to change
The data status changes (from 0 to 1 or from 1 to 0)
NOTE: You can only change one discrete output at a time, but you can change the 16 discretes one by one to get the configuration that is necessary.
NOTE: Discrete outputs return to their normal state when you go out of the DISCRETE OUTPUTS menu.
4.Push the line key adjacent to the RETURN indication until the MCDU menu comes into view.
The MCDU menu comes into view.
5. Close-up
Subtask 73-25-34-862-055-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).