Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) [PW11]
TASK 73-25-34-710-802-A
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
1. Reason for the Job
Use this test to do a check of the Engine Interface Unit (EIU) operation.
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 73-25-34-861-060-A ** ON A/C NOT FOR ALL Subtask 73-25-34-865-072-A ** ON A/C NOT FOR ALL
Subtask 73-25-34-710-064-A ** ON A/C NOT FOR ALL
Subtask 73-25-34-860-085-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:03:27 UTC
Operational Test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS)
1. Reason for the Job
Use this test to do a check of the Engine Interface Unit (EIU) operation.
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-012-A | Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page |
Subtask 73-25-34-861-060-A ** ON A/C NOT FOR ALL Subtask 73-25-34-865-072-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 73-25-34-860-084-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | Q40 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
C. Aircraft Maintenance Configuration
(1) On the ENG section of maintenance panel 50VU:
(a) Lift the guard and push the FADEC GND PWR 1(2) pushbutton switch (the ON legend comes on).
4. Procedure(1) On the ENG section of maintenance panel 50VU:
(a) Lift the guard and push the FADEC GND PWR 1(2) pushbutton switch (the ON legend comes on).
NOTE: After the FADEC is energized, wait ten seconds before you start the test. If you do not wait ten seconds, the interactive mode will stop the EEC self-test and this can cause a spurious fault.
Subtask 73-25-34-710-064-A ** ON A/C NOT FOR ALL
A. Operational Test of the EIU
(1) Do this test.
5. Close-up(1) Do this test.
NOTE: This test is for system 1. For system 2, use the indication between parentheses.
(2) On the left or right MCDU, get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012). | ACTION | RESULT |
|---|---|
| 1.Push the line key adjacent to the EIU1(EIU2) indication. |
|
| 2.Push the line key adjacent to the TESTS indication. |
|
| 3.Push the line key adjacent to the SYSTEM TEST indication. |
|
| 4.Push the line key adjacent to the RETURN indication until the CFDS menu comes into view. |
|
| 5.Stop the MCDU. | |
Subtask 73-25-34-860-085-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the ENG section of maintenance panel 50VU:
(a) Lift the guard push then release the FADEC GND PWR 1(2) pushbutton switch (the ON legend goes off).
Subtask 73-25-34-862-060-A ** ON A/C NOT FOR ALL (1) On the ENG section of maintenance panel 50VU:
(a) Lift the guard push then release the FADEC GND PWR 1(2) pushbutton switch (the ON legend goes off).
Operational Test of the Engine Interface Unit (EIU)