W DOC AIRBUS | AMM A320F

Read the Class 3 Faults [CFMB]


TASK 73-25-34-710-044-A
Read the Class 3 Faults


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
3. Job Set-up
Subtask 73-25-34-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002)
Subtask 73-25-34-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/ENG1/OIL/PRESS2EN1N40
121VUENGINE/ENG1/OIL/QTY1EN1N39
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
FOR FIN: 1000EM2 (ENGINE2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/ENG2/OIL/PRESS2EN2N42
121VUENGINE/ENG2/OIL/QTY1EN2N41
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
121VUENGINE/ENG2/FADEC B4KS2Q40
Subtask 73-25-34-710-052-A ** ON A/C NOT FOR ALL
C. On the left or right MCDU, get SYSTEM REPORT/TEST, ENG (Ref. AMM TASK 31-32-00-860-012).
4. Procedure
Subtask 73-25-34-710-053-A ** ON A/C NOT FOR ALL
A. Do the test below:
ACTION
RESULT
1.Push the line key adjacent to the EIU1 (EIU2) indication.
The EIU menu comes into view.
2.Push the line key adjacent to the CLASS 3 FAULTS.
After a short time, the NO FAILURE message comes into view.
3.Push the MENU pushbutton switch.
The MCDU menu comes into view.
4.Stop the MCDU.

5. Close-up
Subtask 73-25-34-862-051-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 02:59:44 UTC