Check for Erroneous Signal Positions to the Zone Controller from the Bleed and Wing/Nacelle Anti-Ice Valves with Engines, APU and Packs Operating [IAE]
TASK 73-22-00-710-043-A-01
Check for Erroneous Signal Positions to the Zone Controller from the Bleed and Wing/Nacelle Anti-Ice Valves with Engines, APU and Packs Operating
1. Reason for the Job
Refer to the MPD TASK: 732500-I1
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 73-22-00-860-053-A ** ON A/C NOT FOR ALL
Subtask 73-22-00-710-052-A ** ON A/C NOT FOR ALL
Subtask 73-22-00-860-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:00:42 UTC
Check for Erroneous Signal Positions to the Zone Controller from the Bleed and Wing/Nacelle Anti-Ice Valves with Engines, APU and Packs Operating
1. Reason for the Job
Refer to the MPD TASK: 732500-I1
TBD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ARINC READER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-710-018-A | Discontinued Start, Restart and Shutdown Procedures |
| TASK 71-00-00-710-043-A | Normal Engine Automatic-Start Procedure |
| TASK 71-00-00-710-047-A | Normal Engine Manual-Start Procedure |
Subtask 73-22-00-860-053-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Start the APU
(2) Start both engines (Ref. AMM TASK 71-00-00-710-043) or (Ref. AMM TASK 71-00-00-710-047).
(3) On the AIR COND panel 30VU, make sure that the PACK 1/2 pusbutton switches are pushed (the OFF legend is off).
4. Procedure(1) Start the APU
(2) Start both engines (Ref. AMM TASK 71-00-00-710-043) or (Ref. AMM TASK 71-00-00-710-047).
(3) On the AIR COND panel 30VU, make sure that the PACK 1/2 pusbutton switches are pushed (the OFF legend is off).
Subtask 73-22-00-710-052-A ** ON A/C NOT FOR ALL
A. Check of the engine bleed valve, nacelle anti-ice valve and wing anti-ice valve position acquired by zone controller.
(1) Check the engine bleed valve and nacelle anti-ice valve signals.
(a) On the left side of the 800 VU avionic rack, connect an ARINC READER on the system test plug 198VC pins g (hot point) and h (cold point).
(c) On the overhead control and indicating panel 25VU, make sure that wing anti-ice and nacelle anti-ice valves are off (the ON legend is off).
(d) On the AIR COND panel 30VU, make sure that the engine bleed valves are off (the OFF legend is on).
(e) On the AIR COND panel 30VU, select the APU bleed to on (the ON legend is on).
(f) Wait until the position of all the valves is stable on the lower ECAM display unit, on the BLEED page.
(g) Check on the ARINC reader that bits 22 to 27 are all se to 0. This ensures that:
(a) On the AIR COND panel 30VU, select the engine bleed valves to on (the OFF legend is off).
(b) On the AIR COND panel 30VU, select the APU bleed to off (the ON legend is off).
(c) Make sure there is no engine bleed fault.
(d) Check on the ARINC reader that bit 25 is set to 1 and bits 22, 23, 24, 26, 27 are all set to 0. This ensures that there is no wing anti-ice valve position erroneous signal acquired by the zone controller.
(3) On the AIR COND panel 30VU, select the engine bleed valves to off (the OFF legend is on).
5. Close-up(1) Check the engine bleed valve and nacelle anti-ice valve signals.
(a) On the left side of the 800 VU avionic rack, connect an ARINC READER on the system test plug 198VC pins g (hot point) and h (cold point).
NOTE: If the ARINC reader is not supply battery, 28 VDC is available on test plug 198VC pins A and B.
(b) Select label 272. (c) On the overhead control and indicating panel 25VU, make sure that wing anti-ice and nacelle anti-ice valves are off (the ON legend is off).
(d) On the AIR COND panel 30VU, make sure that the engine bleed valves are off (the OFF legend is on).
(e) On the AIR COND panel 30VU, select the APU bleed to on (the ON legend is on).
(f) Wait until the position of all the valves is stable on the lower ECAM display unit, on the BLEED page.
(g) Check on the ARINC reader that bits 22 to 27 are all se to 0. This ensures that:
- there is no bleed valve position erroneous signal acquired by the zone controller
- there is no nacelle anti-ice valve position erroneous signal acquired by the zone controller.
(a) On the AIR COND panel 30VU, select the engine bleed valves to on (the OFF legend is off).
(b) On the AIR COND panel 30VU, select the APU bleed to off (the ON legend is off).
(c) Make sure there is no engine bleed fault.
(d) Check on the ARINC reader that bit 25 is set to 1 and bits 22, 23, 24, 26, 27 are all set to 0. This ensures that there is no wing anti-ice valve position erroneous signal acquired by the zone controller.
(3) On the AIR COND panel 30VU, select the engine bleed valves to off (the OFF legend is on).
Subtask 73-22-00-860-054-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Disconnect the ARINC reader from the left side of the 800 VU.
(2) Shutdown the engines (Ref. AMM TASK 71-00-00-710-018).
(3) Shutdown the APU.
(1) Disconnect the ARINC reader from the left side of the 800 VU.
(2) Shutdown the engines (Ref. AMM TASK 71-00-00-710-018).
(3) Shutdown the APU.