General Visual Inspection of Piping of LPT Case Air Cooling [CFMI]
TASK 72-54-00-210-003-A
General Visual Inspection of Piping of LPT Case Air Cooling
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-54-00-941-055-A ** ON A/C NOT FOR ALL
Subtask 72-54-00-210-051-A ** ON A/C NOT FOR ALL
Subtask 72-54-00-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:33:49 UTC
General Visual Inspection of Piping of LPT Case Air Cooling
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 72-00-00-200-005-A | Over-Serviceable-Limit Extensions |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
Subtask 72-54-00-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-54-00-010-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 72-54-00-040-055-A ** ON A/C NOT FOR ALL Subtask 72-54-00-010-065-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
D. Open the thrust-reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-54-00-210-051-A ** ON A/C NOT FOR ALL
A. Inspect Cooling Air Tubes and Manifolds as Follows
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Cooling air manifold for: | | |
| A.Cracks in mounting lug | One crack on each lug, if not longer than 0.2 in. (5 mm) | |
| B.Cracks in sheet metal | Any number, if not longer than 0.5 in. (12.7 mm) , 1 in. (25.4 mm) apart, and 3 in. (76.2 mm) cumulative length. | Refer to limit extensions (Ref. AMM TASK 72-00-00-200-005). |
| C.Dents | Any number if smooth contour and not deeper than 0.03 in. (0.76 mm). | |
| 2.Cooling air tubes for: | | |
| A.Cracks in tubes | Any number if not longer than 2 in. (50.8 mm) and separated by at least one support member. | |
| B.Dents | Any number, if no more than 30 percent of tube outer diameter. | |
| C.Cracks in tube clamps | Any number if tubes are correctly attached. | |
| 3.Low Pressure Turbine Active Clearance Control (LPTACC) cooling air manifold for: | | |
| A.Cracks | Not serviceable. | |
| B.Dents or flat areas | Any amount if the contour is not more than 20 percent of the original tube outer diameter. | |
| 4.LPTACC cooling air duct for: | | |
| A.Cracks | Not serviceable. | |
| B.Dents or flat areas | Any amount if the contour is not more than 20 percent of the original tube outer diameter. | |
Subtask 72-54-00-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust-reverser cowl doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-54-00-440-055-A ** ON A/C NOT FOR ALL Subtask 72-54-00-410-065-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust-reverser cowl doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Visual Inspection of Piping of LPT Case Air Cooling