Discard Life Limited Parts of HPT and LPT [CFMI]
TASK 72-50-00-920-001-A
Discard Life Limited Parts of HPT and LPT
1. Reason for the Job
Refer to the MPD TASK: 725000-C2
DISCARD LIFE LIMITED PARTS OF HPT AND LPT
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 72-50-00-010-050-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 72-50-00-020-050-A ** ON A/C NOT FOR ALL
Subtask 72-50-00-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:33:46 UTC
Discard Life Limited Parts of HPT and LPT
1. Reason for the Job
Refer to the MPD TASK: 725000-C2
DISCARD LIFE LIMITED PARTS OF HPT AND LPT
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-000-040-A | Removal of the Power Plant |
| TASK 71-00-00-000-040-A-01 | Removal of the Power Plant with the Engine Positioner TWW 75E |
| TASK 71-00-00-000-040-A-03 | Removal of the Power Plant with Jacxson Tool |
| TASK 71-00-00-400-040-A | Installation of the Power Plant |
| TASK 71-00-00-400-040-A-01 | Installation of the Power Plant with the Engine Positioner TWW 75E |
| TASK 71-00-00-400-040-A-03 | Installation of the Power Plant with Jacxson Tool |
Subtask 72-50-00-010-050-A ** ON A/C NOT FOR ALL 4. Procedure
Subtask 72-50-00-020-050-A ** ON A/C NOT FOR ALL
A. Remove and discard life limited parts of the high pressure turbine and the low pressure turbine ESM 720052 and ESM 720054 .
5. Close-upNOTE: ESM 051103 and ESM 051104 for time limits.
Subtask 72-50-00-410-050-A ** ON A/C NOT FOR ALL