Inspection of Forward Acoustical Panels [CFMI]
TASK 72-23-00-280-025-A
Inspection of Forward Acoustical Panels
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 72-23-00-941-102-A ** ON A/C NOT FOR ALL
Subtask 72-23-00-350-065-A ** ON A/C NOT FOR ALL
Subtask 72-23-00-410-121-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:33:43 UTC
Inspection of Forward Acoustical Panels
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 72-23-00-000-002-A | Removal of the Forward Acoustical Panels of the Fan |
| TASK 72-23-00-300-026-A | Repair of Forward, Mid and Aft Acoustical Panels when Missing Cup |
| TASK 72-23-00-400-002-A | Installation of the Forward Acoustical Panels of the Fan |
| TASK 72-23-00-400-045-A | Installation of the Acoustical Panels Attachment Screw Locking |
Subtask 72-23-00-941-102-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
(4) Put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
(5) Put an ACCESS PLATFORM 1M(3 FT) in position at the front of the engine.
4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
(4) Put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
(5) Put an ACCESS PLATFORM 1M(3 FT) in position at the front of the engine.
Subtask 72-23-00-350-065-A ** ON A/C NOT FOR ALL
A. Inspection of FWD Acoustical Panels
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Missing protective coating | No limit | |
| 2.Superficial cracks in Tedlar film | No limits in number | Do periodical checks of the acoustical panels for delamination |
| 3.Deep cracks from bolt holes | A maximum of 2 thrucracks with 0.6 in. (15.24 mm) max length starting from attachment holes | Do periodical checks of the acoustical panels for delamination |
| 4.Delamination | Not serviceable | Replace panel(s) (Ref. AMM TASK 72-23-00-000-002) and (Ref. AMM TASK 72-23-00-400-002) |
| 5.Nicks, dents or impingement mark | No limits in number | |
| 6.Distortion | No limit | |
| 7.Pierced cups caused by screw head | Not serviceable | Install the panel (Ref. AMM TASK 72-23-00-400-045) |
| 8.Unbounded cups | Not serviceable | Repair the panel (Ref. AMM TASK 72-23-00-300-026) and re-install the panel immediately (Ref. AMM TASK 72-23-00-400-002). |
Subtask 72-23-00-410-121-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).