W DOC AIRBUS | AMM A320F

De-activation of the Frangible Drain Mast [CFMB]


TASK 71-71-42-040-045-A
De-activation of the Frangible Drain Mast


ZONE: 400
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
CDL 71-01
Frangible Drain Mast
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-11-000-804-C
Removal of the Drain Mast Seal of the Fan Cowl Door
TASK 71-13-11-400-804-C
Installation of the Drain Mast Seal of the Fan Cowl Door
TASK 71-71-42-000-041-A
Removal of the Drain Mast
3. Job Set-up
Subtask 71-71-42-010-062-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Procedure
Subtask 71-71-42-020-059-A ** ON A/C NOT FOR ALL
A. Remove the remaining part of frangible drain mast (Ref. AMM TASK 71-71-42-000-041).
Subtask 71-71-42-210-055-A ** ON A/C NOT FOR ALL
B. Before each flight, without opening of the fan cowl doors:
   (1) Do an inspection of the fan-cowl drain-mast seals for wear, damage, hole and tear deformation of the curved sections of the seal along the lower edge of the fan cowl doors.
Subtask 71-71-42-960-051-A ** ON A/C NOT FOR ALL
C. Replace worn or damaged parts (Ref. AMM TASK 71-13-11-000-804) and (Ref. AMM TASK 71-13-11-400-804).
[Rev.10 from 2021] 2026.04.02 06:32:29 UTC