Reactivation of the Air Inlet Hoisting Points Plugs [CFML]
TASK 71-60-00-440-801-A
Reactivation of the Air Inlet Hoisting Points Plugs
CDL 71-06
NAI Hoisting Point Plug
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 71-60-00-941-051-A
Subtask 71-60-00-440-050-A
Subtask 71-60-00-860-051-A
[Rev.10 from 2021]
2026.04.02 06:33:31 UTC
Reactivation of the Air Inlet Hoisting Points Plugs
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobCDL 71-06
NAI Hoisting Point Plug
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 71-60-00-941-051-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-60-00-010-053-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Put a ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position near the air inlet.
4. Procedure(1) Put a ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position near the air inlet.
Subtask 71-60-00-440-050-A
A. Reactivation of the Air Inlet Hoisting Point Plugs
(1) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) from the hoisting points.
(2) Clean the area around the hoisting points with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with general Non Aqueous Cleaner-General - - (Material No.08BAA9)
(3) Install the hoisting point plugs:
(a) Install the hoisting point plugs in the holes.
5. Close-up(1) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) from the hoisting points.
(2) Clean the area around the hoisting points with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with general Non Aqueous Cleaner-General - - (Material No.08BAA9)
(3) Install the hoisting point plugs:
(a) Install the hoisting point plugs in the holes.
NOTE: There are four holes.
(b) Make sure that the hoisting point plugs are flush ( 0 +0.0 in. or -0.01 in. (0.00 +0.00 mm or -0.25 mm) / aerodynamic B area tolerances) with the wet surface of the outer barrel and lip. Subtask 71-60-00-860-051-A
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Air Inlet Hoisting Point Plugs