Installation of the Fan Cowl Latches Monitoring Harness [CFML]
TASK 71-51-43-400-802-A
Installation of the Fan Cowl Latches Monitoring Harness
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 71-51-43-941-073-A
Subtask 71-51-43-420-078-A
Subtask 71-51-43-865-115-A
[Rev.10 from 2021]
2026.04.02 06:33:27 UTC
Installation of the Fan Cowl Latches Monitoring Harness
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 4146KS
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CPNCL00700) | ELECTRICAL BONDING COATING (BLUE COLOR) |
| (Material No.CPNCL01420) | SEALANT LOW DENSITY-FUEL TANK & GP |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | NUT | AIPC 71-13-10-22-030 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 73-25-34-710-805-A | Operational Test of the Engine Interface Unit (with CFDS) |
Subtask 71-51-43-941-073-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
Subtask 71-51-43-865-114-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 71-51-43-010-090-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
C. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
4. Procedure(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position.
Subtask 71-51-43-420-078-A
A. Installation of the Latches Monitoring Harness
(1) Carefully put the latches monitoring harness (1) in position on the fan cowl door.
(2) Remove the CAP - BLANKING from the electrical connectors on the latches monitoring harness (1) and from the upper connector.
(3) Install the latches monitoring harness (1) with the screws (4), washers (2) and new AIPC 71-13-10-22-030 NUT (3) on the upper electrical support.
(4) Apply SEALANT LOW DENSITY-FUEL TANK & GP (Material No.CPNCL01420) andCPNCL00700 ELECTRICAL BONDING COATING (BLUE COLOR) on the electrical bonding (Ref. AMM TASK 20-28-00-912-802).
(5) Connect the upper connector with the latches monitoring harness (1).
(6) Install the latches monitoring harness (1) with the screws (5) and (10), washers (6) and (9) and clamps (7), (8) and (11) on the fan cowl door electrical supports.
(7) Remove the CAP - BLANKING from the electrical connectors on the latches monitoring harness (1) and from the proximity sensors.
(8) Connect the latches monitoring harness connectors (1) to the proximity sensors:
(a) Carefully connect the latches monitoring harness connectors (1) to the proximity sensors.
(b) Turn the connector nut clockwise until get connection.
1 Turn clockwise each connector until the red mark of the proximity sensor is hidden.
2 When the red marking is hidden, turn each connector by hand until you hear two "clicks".
5. Close-up(1) Carefully put the latches monitoring harness (1) in position on the fan cowl door.
(2) Remove the CAP - BLANKING from the electrical connectors on the latches monitoring harness (1) and from the upper connector.
(3) Install the latches monitoring harness (1) with the screws (4), washers (2) and new AIPC 71-13-10-22-030 NUT (3) on the upper electrical support.
(4) Apply SEALANT LOW DENSITY-FUEL TANK & GP (Material No.CPNCL01420) and
(5) Connect the upper connector with the latches monitoring harness (1).
(6) Install the latches monitoring harness (1) with the screws (5) and (10), washers (6) and (9) and clamps (7), (8) and (11) on the fan cowl door electrical supports.
(7) Remove the CAP - BLANKING from the electrical connectors on the latches monitoring harness (1) and from the proximity sensors.
(8) Connect the latches monitoring harness connectors (1) to the proximity sensors:
(a) Carefully connect the latches monitoring harness connectors (1) to the proximity sensors.
(b) Turn the connector nut clockwise until get connection.
NOTE: The connector must not hide the red mark on the proximity sensor.
(c) Tighten the latches monitoring harness connectors by hand: 1 Turn clockwise each connector until the red mark of the proximity sensor is hidden.
2 When the red marking is hidden, turn each connector by hand until you hear two "clicks".
Subtask 71-51-43-865-115-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 71-51-43-410-072-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 71-51-43-710-072-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
C. Do the operational test of the Engine Interface Unit (EIU) with the Centralized Fault Display System (CFDS) (Ref. AMM TASK 73-25-34-710-805).
Latches Monitoring Harness