W DOC AIRBUS | AMM A320F

Removal of the Fan Cowl Latches Monitoring Harness [CFML]


TASK 71-51-43-000-802-A
Removal of the Fan Cowl Latches Monitoring Harness


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4146KS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
3. Job Set-up
Subtask 71-51-43-941-072-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-51-43-865-113-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
121VUENGINE/LATCH DOORS & SLATS/ENG193KS1P39
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/LATCH DOORS & SLATS/ENG293KS2P40
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
Subtask 71-51-43-010-089-A
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 71-51-43-020-082-A
A. Removal of the Latches Monitoring Harness
   (1) Disconnect the latches monitoring harness connector from the proximity sensors.
   (2) Put CAP - BLANKING on the disconnected connectors.
   (3) Disconnect the upper connector from the latches monitoring harness.
   (4) Record the positions of the bonding points.
   (5) Put CAP - BLANKING on the disconnected connectors.
   (6) Remove the screws (4), (5) and (10), washers (2), (6) and (9) and nuts (3). Discard the nuts (3).
NOTE: Keep the clamps (7), (8) and (11) installed on the latches monitoring harness (1).
   (7) Remove the latches monitoring harness (1) from the fan cowl door.
[Rev.10 from 2021] 2026.04.02 06:33:27 UTC