Removal of the Fan Cowl Latches Monitoring Harness [CFML]
TASK 71-51-43-000-802-A
Removal of the Fan Cowl Latches Monitoring Harness
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-51-43-941-072-A
Subtask 71-51-43-020-082-A
[Rev.10 from 2021]
2026.04.02 06:33:27 UTC
Removal of the Fan Cowl Latches Monitoring Harness
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4146KS
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
Subtask 71-51-43-941-072-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-51-43-865-113-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 71-51-43-010-089-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG1 | 93KS1 | P39 |
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| 121VU | ENGINE/LATCH DOORS & SLATS/ENG2 | 93KS2 | P40 |
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 71-51-43-020-082-A
A. Removal of the Latches Monitoring Harness
(1) Disconnect the latches monitoring harness connector from the proximity sensors.
(2) Put CAP - BLANKING on the disconnected connectors.
(3) Disconnect the upper connector from the latches monitoring harness.
(4) Record the positions of the bonding points.
(5) Put CAP - BLANKING on the disconnected connectors.
(6) Remove the screws (4), (5) and (10), washers (2), (6) and (9) and nuts (3). Discard the nuts (3).
(1) Disconnect the latches monitoring harness connector from the proximity sensors.
(2) Put CAP - BLANKING on the disconnected connectors.
(3) Disconnect the upper connector from the latches monitoring harness.
(4) Record the positions of the bonding points.
(5) Put CAP - BLANKING on the disconnected connectors.
(6) Remove the screws (4), (5) and (10), washers (2), (6) and (9) and nuts (3). Discard the nuts (3).
NOTE: Keep the clamps (7), (8) and (11) installed on the latches monitoring harness (1).
(7) Remove the latches monitoring harness (1) from the fan cowl door.
Latches Monitoring Harness