Removal of the Fan Cowl Keeper Proximity Sensor [CFML]
TASK 71-13-51-000-801-A
Removal of the Fan Cowl Keeper Proximity Sensor
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-51-941-050-A
Subtask 71-13-51-020-050-A
[Rev.10 from 2021]
2026.04.02 06:33:23 UTC
Removal of the Fan Cowl Keeper Proximity Sensor
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
Subtask 71-13-51-941-050-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-51-010-050-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) is in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 71-13-51-020-050-A
A. Removal of the Sheet Metal Protection
(1) Remove the bolts (3) and washers (2).
(2) Remove the sheet metal protections (1), (4) and (5) from the fan cowl door.
Subtask 71-13-51-020-051-A (1) Remove the bolts (3) and washers (2).
(2) Remove the sheet metal protections (1), (4) and (5) from the fan cowl door.
B. Removal of the Fan Cowl Keeper Proximity Sensor (PRE SPOL BD-FC-19004)
(2) Put a CAP - BLANKING on the disconnected connector (6).
(3) Remove the nut (11), lock washer (10), washer (9) and the peeling washer (8).
(4) Remove the fan cowl keeper proximity sensor (7).
(5) Put a CAP - BLANKING on the fan cowl keeper proximity sensor (7).
Subtask 71-13-51-020-053-A CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the latches monitoring harness connector (6) from the fan cowl keeper proximity sensor (7). (2) Put a CAP - BLANKING on the disconnected connector (6).
(3) Remove the nut (11), lock washer (10), washer (9) and the peeling washer (8).
NOTE: Each fan cowl keeper proximity sensor (7) with its peeling washer (8) has to be installed in the same location.
(a) Discard the lock washer (10). (4) Remove the fan cowl keeper proximity sensor (7).
(5) Put a CAP - BLANKING on the fan cowl keeper proximity sensor (7).
C. Removal of the Fan Cowl Keeper Proximity Sensor (POST SPOL BD-FC-19004)
(2) Put a CAP - BLANKING on the disconnected connector (6).
(3) Remove the nut (11), nut (10), washer (9) and the peeling washer (8).
(5) Put a CAP - BLANKING on the fan cowl keeper proximity sensor (7).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the latches monitoring harness connector (6) from the fan cowl keeper proximity sensor (7). (2) Put a CAP - BLANKING on the disconnected connector (6).
(3) Remove the nut (11), nut (10), washer (9) and the peeling washer (8).
NOTE: Each fan cowl keeper proximity sensor (7) with its peeling washer (8) has to be installed in the same location.
(4) Remove the fan cowl keeper proximity sensor (7).(5) Put a CAP - BLANKING on the fan cowl keeper proximity sensor (7).
Fan Cowl Keeper Proximity Sensor