General Visual Inspection of the Fan Cowl Doors [CFML]
TASK 71-13-11-200-806-A
General Visual Inspection of the Fan Cowl Doors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-11-941-087-A
Subtask 71-13-11-210-074-A
Subtask 71-13-11-410-077-A
[Rev.10 from 2021]
2026.04.02 06:33:19 UTC
General Visual Inspection of the Fan Cowl Doors
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
CAUTION:
DO NOT EXTEND THE SLATS WHEN THE FAN COWLS AND THE THRUST REVERSER COWLS ARE OPEN. IF YOU DO THIS, DAMAGE TO THE AIRCRAFT CAN OCCUR.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| SRM 542000 |
Subtask 71-13-11-941-087-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-13-11-010-083-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Get access to the left and right fan-cowl doors.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure(1) Get access to the left and right fan-cowl doors.
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 71-13-11-210-074-A
A. Do the General Visual Inspection of the External Side of the Left and Right Fan-Cowl Doors.
(1) On the external side of the left and right fan-cowl doors, do the inspections that follow:
(3) On the external side of the left and right fan-cowl doors, do the inspections that follow:
Subtask 71-13-11-080-063-A (1) On the external side of the left and right fan-cowl doors, do the inspections that follow:
- External skin
- Strake structure and fixations
- Access doors and surrounding structure: CLP flag, Integrated Drive Generator (IDG) and oil tank door
- Ventilation grip and surrounding structure
- Forward and aft edges of the fan cowl door.
(3) On the external side of the left and right fan-cowl doors, do the inspections that follow:
- Access doors and surrounding structure: starter flapper door
- Interphone jack (optional)
- Hoisting points and plugs.
B. Removal of the Access Platform
(1) Remove the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE.
Subtask 71-13-11-010-084-A (1) Remove the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE.
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 71-13-11-010-085-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
D. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 71-13-11-210-075-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
E. Do the General Visual Inspection of the Internal Side of the Left and Right Fan-Cowl Doors
(1) On the internal side of the left and right fan-cowl doors, do the inspections that follow:
(3) On the internal side of the left and right fan-cowl doors, do the inspections that follow:
5. Close-up(1) On the internal side of the left and right fan-cowl doors, do the inspections that follow:
- Internal skin: skin, RTM beams and circumferential stiffeners
- Ventilation grids
- Forward and aft edges of the fan cowl door.
(3) On the internal side of the left and right fan-cowl doors, do the inspections that follow:
- Electrical CLP: the harness and connectors
- Mechanical CLP: teleflex, flag box assy
- Interphone jack (optional)
- Hold-open rods
- Keeper housings (only external surface) and latch housing
- Locators and guide ramps
- Access doors surrounding surface.
Subtask 71-13-11-410-077-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).