Functional Check of Fan Cowl Latch Tension [IAE]
TASK 71-13-00-800-010-A
Functional Check of Fan Cowl Latch Tension
1. Reason for the Job
Refer to the MPD TASK: 711300-I2
FUNCTIONAL CHECK OF FAN COWL LATCH TENSION
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-13-00-941-054-A ** ON A/C NOT FOR ALL
Subtask 71-13-00-720-050-A ** ON A/C NOT FOR ALL
Subtask 71-13-00-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:29:12 UTC
Functional Check of Fan Cowl Latch Tension
1. Reason for the Job
Refer to the MPD TASK: 711300-I2
FUNCTIONAL CHECK OF FAN COWL LATCH TENSION
NOTE: SBN71-0331 (equivalent to Airbus service bulletin SB 71-1069) introduces a lockable latch in the forward position (latch number 1) that must be opened and closed and locked with a key and flag assembly. The key and flag assembly are stowed in the cockpit and must not be used if there is damage to the key or flag.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-800-011-A | Adjustment of the Fan Cowl Spigots and Bumpers |
| TASK 71-13-00-800-011-A | Adjustment of the Fan Cowl Spigots and Bumpers (for corrective action) |
Subtask 71-13-00-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-13-00-720-050-A ** ON A/C NOT FOR ALL
A. Do this test:
Subtask 71-13-00-010-053-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| Use feeler gages to measure Dimension X. | Dimension X should be 0 in. (0.0 mm). |
| If Dimension X is not 0 in. (0.0 mm) adjustment is necessary (Ref. AMM TASK 71-13-00-800-011). | |
B. Open each of the four latches on the fan cowls (Ref. AMM TASK 71-13-00-010-010)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 71-13-00-720-051-B ** ON A/C NOT FOR ALL NOTE: The tension on each latch is measured with the other three latches in the closed position.
(1) FOR [1000EM1] (ENGINE-1)437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
C. Do this test:
5. Close-up| ACTION | RESULT |
|---|---|
| Use the SPRING BALANCE 30 DAN (72 LBF) on the end of the latch handle (15) and measure the force necessary to close each of the four latches. | The force necessary to close each of the four latches must be between 30 lbf (13.34 daN) and 40 lbf (17.79 daN). If the force is not in the limits given, adjustment is necessary (Ref. AMM TASK 71-13-00-800-011). |
Subtask 71-13-00-410-053-A ** ON A/C NOT FOR ALL
Spigot and Bumper Adjustment