W DOC AIRBUS | AMM A320F

General Visual Inspection of Inner Surface of Doors and Seals [IAE]


TASK 71-13-00-210-803-A
General Visual Inspection of Inner Surface of Doors and Seals


1. Reason for the Job
Refer to the MPD TASK: 711300-I4
GENERAL VISUAL INSPECTION OF INNER SURFACE OF DOORS AND SEALS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
LIGHT SOURCE - INSPECTION
No specific
1
MIRROR - INSPECTION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
NSRM 542000
3. Job Set-up
Subtask 71-13-00-941-070-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 71-13-00-010-084-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 71-13-00-350-050-A ** ON A/C NOT FOR ALL
A. Visually examine the Fan Cowls
   (1) Use the LIGHT SOURCE - INSPECTION and MIRROR - INSPECTION and inspect these parts for damage:
     (a) The internal surface of the fan cowl.
     (b) The seals of the fan cowl.
   (2) Make sure that there are no signs of corrosion, cracks or damage.
   (3) If one or more of these parts are damaged, refer to NSRM 542000 for allowable damage data.
5. Close-up
Subtask 71-13-00-942-058-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:29:22 UTC