W DOC AIRBUS | AMM A320F

General Visual Inspection of the Fan Cowl Door Hinge Fittings [IAE]


TASK 71-13-00-210-010-A
General Visual Inspection of the Fan Cowl Door Hinge Fittings


1. Reason for the Job
Refer to the MPD TASK: 711300-03
GENERAL VISUAL INSPECTION OF FAN COWL DOOR HINGE FITTINGS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
SRM 511100
SRM 512200
3. Job Set-up
Subtask 71-13-00-941-063-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-13-00-010-066-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
   (2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (3) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (4) Put the ACCESS PLATFORM 2M (6 FT) in to position.
4. Procedure
Subtask 71-13-00-220-054-A ** ON A/C NOT FOR ALL
A. Do a general visual inspection of the fan cowl hinge fittings
F Fan Cowl Hinge Fittings ** ON A/C NOT FOR ALL
   (1) Make sure that there are no signs of corrosion, cracks or damage.
   (2) Make sure that all installations are correct.
Subtask 71-13-00-220-060-A ** ON A/C NOT FOR ALL
B. Do a visual inspection of the fan cowl hinge fittings on pylon side
   (1) Make sure that there is no:
     (a) Corrosion damage:
  • If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for types, inspection, removal and corrosion protection.
     (b) Other damage (cracks, scratches, stress, marks, dents, bumps, etc.):
  • If you find other damage, refer to the structural Repair Manual SRM 511100 for damage classification and corrective action.
5. Close-up
Subtask 71-13-00-410-071-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
   (3) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (4) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
     (a) Remove the access platform(s).
     (b) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:29:20 UTC